Instruction Manual for MODEL A9

11-0

□,

A9

12-0

 

2/8 

Upper terminals (without BCD outputs)

 

 

 

 

 

 

 

 

 

Upper terminals

with BCD outputs

 

 

 

 

 

 

 

 

Upper Connector : HIF-3BA-34PA-2.54DS 

                                                                  (HIROSE) 

Attachment Upper Connector : HIF-3BA-34D-2.54R 

                                                                                      (HIROSE) 

1 to 17

  Outputs of bits 1,2,4 and 8 of each digit 

18

BCD polarity output 

19

BCD overrange output 

20

BCD PC (print control) output 

21

BCD enable input 

Connecting this terminal to COM terminal or bringing the potential of 
this 

terminal to “0” level causes BCD  outputs to  be high impedance 

or transistors to be turned off. 

In the case of “without BCD output” option, terminals 1 to 21 are no 

connection. 

 

22,30,33,34

NC 

Do not connect anything to the NC terminals. 

23-26

COM 

Common terminals for BCD outputs and control terminals. 

27

Hold input 

By shorting this terminal to COM terminal or bringing its potential to 
the 

“0” level, the panelmeter maintains its indication.   

28

Peak hold input 

By shorting this terminal to COM terminal or bringing its potential to 

the  “0”  level,

 

the  panelmeter  displays  maximum  value  (Peak  hold), 

minimum  value  (Valley  hold)  or  the  difference  value  between  the 
maximum  value  and  the  minimum  value  (Peak-Valley  hold).  These 
functions can be switched by using condition data. 

29

Digital Zero input 

By shorting this terminal to COM terminal or bringing its potential to 

the “0” level,

 

  the panelmeter performs measurements with the latest 

displayed value as zero and displays the width of variations from that 
point onward. 

31,32:

 

Pattern select inputs 

By combining states of P.SEL0 and P.SEL1 terminals (connecting  or 
not to the COM terminal 

/ bringing its potential to the “0” level or the 

“1” level),    the panelmeter uses one of the 4 patterns of scaling data 
set by scaling data setting. 

*

”0” level

0-1.5V

, 

”1” level

3.5-5V 

Input current

-0.5mA

 

 

 

 

 

 

 

4.Parameter Settings 

4.1 Components and Functions 

  Before  setting  parameters,  remove  the  front  panel  by  inserting  a 

flat-blade screwdriver into the ditch under the front panel. 

 
 
 
 
 
 
 

 

 

Main display

 

- displays a measured value during 

measurment operation or a menu or 
parameter information during parameter 
setting mode. 

Enter key

 

- Shifts from measurment operation to 

parameter setting mode. 

(

“Enter”+“Mode”) 

Mode key

 

- In the parameter setting mode, switches 

items to be set. 

- Shifts from measurment operation to 

display shift setting mode. 

(“Mode”+“Shift”) 

Shift key

 

- In the parameter setting mode, switches   

digits to be set.   

- Shifts from measurment operation to 

display shift setting mode. 
(“Mode”+“Shift”) 

increment key

 

- In the parameter setting mode, selects 

numeric data (increment) or options for 
each parameter. 

*

“XXXX”+“YYYY”  means  pushing  “YYYY”  key  with  pushing 

“XXXX”key. 

 

Function monitoring indicator

 

Name 

functions 

Measurement mode 

Parameter setting 

mode 

DZ 

Lights while Digital Zero is ON. 

Blinks  while  setting 
output value for each 
linearize point. 

PH 

Lights  while  Peak  Hold  ,  Valley 
Hold or Peak-Valley Hold is ON. 

Lights-out

 

ME 

Lights  while  Digital  Zero  Backup 
is ON. 

Lights-out

 

RE 

Lights  under  Remote  Control 
condition  by  the  communication 
function. 

* This function is not available for 

this model.

 

Blinks  while  setting 
input  value  for  each 
linearize point. 

 
P.S1 
 

Indicates 

the 

number 

of 

selected pattern of scaling data. 

P.S1  OFF,P.S0  OFF 

pattern 

No.1 

P.S1  OFF,P.S0  ON   

pattern 

No.2 

P.S1  ON,  P.S0  OFF 

pattern 

No.3 

P.S1  ON,  P.S0  ON   

pattern 

No.4 

 
 
 

Lights-out

 

 
P.S0 
 

 

 

* If Digital Zero Backup (B. UP) in the condition data is set to OFF, Digital Zero 

value will be cleared by power-off.

 

 
 
 
 
 
 

 

▲ 

M 

E 

3 4

3 3

2

1

1 0

1 0

1 0

1 0

3

2

1

0

1 0

1 0

1 0

1 0

3

2

1

0

1 0

4

PO

L

NC

PC

NC

CO

M

NC

OV

ER

E

NA

BL

E

S/

H

PH

D

Z

NC

P.

SE

L

P.

S

E

L

0

CO

M

CO

M

CO

M

1

3 4

3 3

2

1

NC

NC

CO

M

NC

S/

H

PH

DZ

NC

P.

SE

L

1

P.

S

E

L0

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

NC

CO

M

CO

M

CO

M

Summary of Contents for A9000 Series

Page 1: ...12 22 or 23 range Input terminal HI input terminal of 13 or 14 24 or 25 range Input terminal LO input terminal Selecting input range can not be done only by connecting input signal to a suitable termi...

Page 2: ...vel 3 5 5V Input current 0 5mA 4 Parameter Settings 4 1 Components and Functions Before setting parameters remove the front panel by inserting a flat blade screwdriver into the ditch under the front p...

Page 3: ...item 5 Press the Mode key to move to peak hold type setting 6 Set up the peak hold type using the Increment key This setting example sets peak hold type to PH PH Holds the maximum display value PV Ho...

Page 4: ...Enter and Mode keys during measurement operation to enter the condition data setting mode 2 Press the Shift key to move to the scaling data setting mode 3 Press the Mode key to display the number of...

Page 5: ...the setting again The number of linearize points is up to 16 but a value 17 to 19 is also displayed during setup Note that if you set a value from 17 to 19 it is forced to set to 16 5 Other Functions...

Page 6: ...23 19 999mA 24 199 99mA 0 1 3A 25 1999 9mA Common specifications A D conversion conversion method Input circuit Single ended Setting sampling rate 25times sec max Overrange warning For an input signa...

Page 7: ...ble ON disable OFF of the linearize function and data clear CLR TR T Tracking zero correction time 00 PL0 00 99 Sets the correction time of the tracking zero function Every TR T setting sampling perio...

Page 8: ...period 1 25 times sec 40ms 20 1 25 times sec 800ms 2 12 5 times sec 80ms 40 0 625 times sec 1 6s 4 6 25 times sec 160ms 80 0 3125 times sec 3 2s 8 3 125 times sec 320ms 100 0 25 times sec 4s 10 2 5 ti...

Reviews: