Instruction Manual for MODEL A9
□
11-0
□,
A9
□
12-0
□
2/8
Upper terminals (without BCD outputs)
Upper terminals
(
with BCD outputs
)
Upper Connector : HIF-3BA-34PA-2.54DS
(HIROSE)
Attachment Upper Connector : HIF-3BA-34D-2.54R
(HIROSE)
1 to 17
:
Outputs of bits 1,2,4 and 8 of each digit
18
:
BCD polarity output
19
:
BCD overrange output
20
:
BCD PC (print control) output
21
:
BCD enable input
・
Connecting this terminal to COM terminal or bringing the potential of
this
terminal to “0” level causes BCD outputs to be high impedance
or transistors to be turned off.
*
In the case of “without BCD output” option, terminals 1 to 21 are no
connection.
22,30,33,34
:
NC
・
Do not connect anything to the NC terminals.
23-26
:
COM
・
Common terminals for BCD outputs and control terminals.
27
:
Hold input
・
By shorting this terminal to COM terminal or bringing its potential to
the
“0” level, the panelmeter maintains its indication.
28
:
Peak hold input
・
By shorting this terminal to COM terminal or bringing its potential to
the “0” level,
the panelmeter displays maximum value (Peak hold),
minimum value (Valley hold) or the difference value between the
maximum value and the minimum value (Peak-Valley hold). These
functions can be switched by using condition data.
29
:
Digital Zero input
・
By shorting this terminal to COM terminal or bringing its potential to
the “0” level,
the panelmeter performs measurements with the latest
displayed value as zero and displays the width of variations from that
point onward.
31,32:
Pattern select inputs
・
By combining states of P.SEL0 and P.SEL1 terminals (connecting or
not to the COM terminal
/ bringing its potential to the “0” level or the
“1” level), the panelmeter uses one of the 4 patterns of scaling data
set by scaling data setting.
*
”0” level
:
0-1.5V
,
”1” level
:
3.5-5V
(
Input current
:
-0.5mA
)
4.Parameter Settings
4.1 Components and Functions
※
Before setting parameters, remove the front panel by inserting a
flat-blade screwdriver into the ditch under the front panel.
①
Main display
- displays a measured value during
measurment operation or a menu or
parameter information during parameter
setting mode.
②
Enter key
- Shifts from measurment operation to
parameter setting mode.
(
“Enter”+“Mode”)
③
Mode key
- In the parameter setting mode, switches
items to be set.
- Shifts from measurment operation to
display shift setting mode.
(“Mode”+“Shift”)
④
Shift key
- In the parameter setting mode, switches
digits to be set.
- Shifts from measurment operation to
display shift setting mode.
(“Mode”+“Shift”)
⑤
increment key
- In the parameter setting mode, selects
numeric data (increment) or options for
each parameter.
*
“XXXX”+“YYYY” means pushing “YYYY” key with pushing
“XXXX”key.
⑥
Function monitoring indicator
Name
functions
Measurement mode
Parameter setting
mode
DZ
Lights while Digital Zero is ON.
Blinks while setting
output value for each
linearize point.
PH
Lights while Peak Hold , Valley
Hold or Peak-Valley Hold is ON.
(
Lights-out
)
ME
Lights while Digital Zero Backup
is ON.
(
Lights-out
)
RE
Lights under Remote Control
condition by the communication
function.
(
* This function is not available for
this model.
)
Blinks while setting
input value for each
linearize point.
P.S1
Indicates
the
number
of
a
selected pattern of scaling data.
P.S1 OFF,P.S0 OFF
:
pattern
No.1
P.S1 OFF,P.S0 ON
:
pattern
No.2
P.S1 ON, P.S0 OFF
:
pattern
No.3
P.S1 ON, P.S0 ON
:
pattern
No.4
(
Lights-out
)
P.S0
* If Digital Zero Backup (B. UP) in the condition data is set to OFF, Digital Zero
value will be cleared by power-off.
①
②
③
④
⑤
⑥
▲
▲
M
E
2
8
2
8
2
8
2
8
1
4
1
4
1
4
1
4
3 4
3 3
2
1
1 0
1 0
1 0
1 0
3
2
1
0
1 0
1 0
1 0
1 0
3
2
1
0
1
1 0
4
PO
L
NC
PC
NC
CO
M
NC
OV
ER
E
NA
BL
E
S/
H
PH
D
Z
NC
P.
SE
L
P.
S
E
L
0
CO
M
CO
M
CO
M
1
3 4
3 3
2
1
NC
NC
CO
M
NC
S/
H
PH
DZ
NC
P.
SE
L
1
P.
S
E
L0
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
CO
M
CO
M
CO
M