Applying a voltage or current exceeding its maximum permissible value may cause the 

unit to be damaged. 

(2)

 

Always use the unit within the specified voltage range: otherwise, it may cause a fire,   

electric shock or personal/equipment damage.   

(3)  For  the  purpose  of  functional  improvement,  the  information  written  herein  may  be 

changed

 

without prior notice.   

(4) Information contained herein is considered accurate to the best of our knowledge.   

If  you  have  any  question  or  comment  on  the  information,  please  contact  us  or  our 

distributor. 

(5)

 

Read this manual carefully and thoroughly before starting to operate the unit,   

and keep the manual available for future reference. 

 

1. Before Using the Unit 

Thank you for purchasing our A9000 Series Digital Panelmeter. Please 
make sure that the operator who uses the panelmeter keeps the manual 
on  hand.  Also,  the  meter  should  be  checked  upon  receipt  for  damage 
that  might  have  occurred  while  in  transit.  Should  the  product  be 
damaged or any accessory be missing, notify your sales representative 
or our sales office directly. 

1.1.  Model and Suffix Code Configuration 

 
The  model  and  suffix  code  of  the  A9000  series  are  as  shown  below. 
Check  that  the  product  received  matches  the  one  you  selected  when 
ordering. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.2.

 

    Checking the Accessories   

The  A9000  series  accessories  include  one  copy  of  this  instruction 
manual,  one  unit  label  and  a  connector

 

for  BCD  outputs  /  external 

control inputs. 
 

2.

 

 

Mounting Method 

2.1.

 

 

Panel Cutout Size 

Panel cutout size for mounting the A9000 series digital panelmeter is as 

shown below: 

2.2 External Dimensions 

 

2.3 How to Mount the Unit on the Panel 

 

 

(1)  Do  not  install  the  unit  where  it  is  exposed  to  dust,  particles,  chemicals  harmful  to 

electric components, corrosive gases, etc. 

(2) When this unit is installed inside other equipment, pay attention to the  heat radiation 

and keep the heat inside the equipment 50°C or below. 

(3) Exercise care so that the product is not subject to vibrations or shocks.

 

 

3.

 

Terminals and Connections

 

 

 

 

①:

Input terminal HI (+ input terminal of 11 or 12, 22 or 23 -range )

 

②:

Input terminal HI (+ input terminal of 13 or 14, 24 or 25 -range ) 

③:

Input terminal LO (- input terminal ) 

* Selecting input range can not be done only by connecting input signal 

to a suitable terminal. Please set the RANG parameter in condition data. 
See 

“4.6.(8) Setting condition data”. 

* Make input signal wires as short as possible and keep them away from 

other signal wires. 

* Use two-core shielded cables  in  locations  with  a lot  of  external  noise 
and connect the external sheaths to the LO side of the signal source at 
one point. 
* If harmonic noise is superimposed on an input signal, insert a low-pass 
filter  in  the  input.  However,  care  must  be  exercised  depending  on  the 
usage  conditions  because  a  delay  in  response  time  is  caused  in  time 
constant.

 

 

④⑤⑥:

NC terminals 

*Do not connect anything to the NC terminals. 

⑦:

Power terminal (In case of DC POWER : 0 V) 

⑧:

Power terminal (In case of DC POWER : +V) 

*This panelmeter has no power switch. Connecting it to a power source 
causes it to be operable immediately. 

 

 

 

 

 

 

 

 

 

 

suitable solder less terminals

 

5.8mm or less

 

5.8mm or less

 

Lower Terminals 

 

Instruction Manual for A9000 Series 

  Digital Panelmeter

 

A9□12-0□  for DC Current measurement

 

 

A9□11-0□  for DC Voltage measurement

 

 

(1)After removing the mounting bands, insert 

the main unit into a opening in a panel from 
the front side of the panel.           

 

 

(2)Attach the mounting bands to main unit 

from the rear side of the panel for fixing.           

 

 

Panel (front side) 

 

Panel (rear side) 

 

mounting band 

 

53

 

66.5

 

8.9

 

7.8

 

8.7

 

96

 

91.5

 

48

 

53

 

5

6

.5

 

8

.9

 

Power input terminals 

 

Signal input terminals 

 

BCD output / External control input connector 

 

2015.12 

UX-34076k 

CAUTION 

*Recommended panel thickness: 

  0.8 to 5 mm

 

(Unit: mm)

 

+

 

0

 

.

 

8

 

92

 

MIN 120

 

M

IN 

70

 

-

 

0

 

45

 

+

0

.6

 

-

0

 

CAUTION 

*Every model is provided with external control inputs.

1

DC current

Comparative 

5

B

D

F

AC current (true RMS)

Precess signal

Temparature sensor 

AC large current (true RMS)

4

12-24V DC

DC voltage

AC voltage (true RMS)

1

2

AC large voltage(15range, true RMS)

E

C

6

Temparature sensor 

DC large voltage(15range)

 (thermocouple sensor)

 (resistance tempararure detector)

100-240V AC

Power 

Input

Display

5-12V DC

4

Single

1
3

supply :

3

0

BCD(Open colexternal control inputs

Output

     output :

2

(None)+external control inputs

(None)

1

BCD (TTL)+external control inputs

9

0

□ 1

WATANABE ELECTRIC INDUSTRY CO., LTD.

Summary of Contents for A9000 Series

Page 1: ...12 22 or 23 range Input terminal HI input terminal of 13 or 14 24 or 25 range Input terminal LO input terminal Selecting input range can not be done only by connecting input signal to a suitable termi...

Page 2: ...vel 3 5 5V Input current 0 5mA 4 Parameter Settings 4 1 Components and Functions Before setting parameters remove the front panel by inserting a flat blade screwdriver into the ditch under the front p...

Page 3: ...item 5 Press the Mode key to move to peak hold type setting 6 Set up the peak hold type using the Increment key This setting example sets peak hold type to PH PH Holds the maximum display value PV Ho...

Page 4: ...Enter and Mode keys during measurement operation to enter the condition data setting mode 2 Press the Shift key to move to the scaling data setting mode 3 Press the Mode key to display the number of...

Page 5: ...the setting again The number of linearize points is up to 16 but a value 17 to 19 is also displayed during setup Note that if you set a value from 17 to 19 it is forced to set to 16 5 Other Functions...

Page 6: ...23 19 999mA 24 199 99mA 0 1 3A 25 1999 9mA Common specifications A D conversion conversion method Input circuit Single ended Setting sampling rate 25times sec max Overrange warning For an input signa...

Page 7: ...ble ON disable OFF of the linearize function and data clear CLR TR T Tracking zero correction time 00 PL0 00 99 Sets the correction time of the tracking zero function Every TR T setting sampling perio...

Page 8: ...period 1 25 times sec 40ms 20 1 25 times sec 800ms 2 12 5 times sec 80ms 40 0 625 times sec 1 6s 4 6 25 times sec 160ms 80 0 3125 times sec 3 2s 8 3 125 times sec 320ms 100 0 25 times sec 4s 10 2 5 ti...

Reviews: