3.2. Connecting Input Signal 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

3.3. Connecting Various Output Signals 

3.3.1. 

Relay Contact Output Unit 

 
 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

3.3.2. 

Photocoupler Output Unit

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.3.3. 

BCD Unit

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Instruction Manual for MODEL A7X18-X(Temperature Measurement)                                               2/12   

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Term. 

No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Name

P.SEL1

P.SEL2

P.SEL3

S/H

PH

DZ

COM

HH a

c

HI a

c

GO a

LO a

c

LL a

Description

Pattern Select terminals. Enabled when they have the same 

potential as, or are shorted with, terminal COM. 
* They are disabled unless pattern select is set up for terminal 

control using condition data. 

Common terminal for external control. (It has the same potential as input LO.) 

The a-contact output terminal of HH output relay 

COM terminal for HH and HI output relays 

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

Start/Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM. 

Peak Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM. 

Digital Zero terminal. Enabled when it has the same potential 
as, or is shorted with, terminal COM. 

* This terminal is disabled unless digital zero is set up for 
terminal control using condition data. 

The a-contact output terminal of HI output relay 

The a-contact output terminal of GO output relay 

The a-contact output terminal of LO output relay 

The a-contact output terminal of LL output relay 

COM terminal of GO output relay 

COM terminal for LO and LL output relays 

Adaptable wire: AWG24 to AWG16

Pattern1

Pattern2

Pattern3 Pattern4 Pattern5 Pattern6 Pattern7 Pattern8

P1
P2
P3

Recommended torque : 0.18Nm

Term. 

No.

Name

1

P.SEL1

2

P.SEL2

3

P.SEL3

4

S/H

5

PH

6

DZ

7

COM

8

HH c

9

eCOM

10

HI c

11

eCOM

12

GO c

13

LO c

14

eCOM

15

LL c

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Description

Pattern Select terminals. Enabled when they have the same 

potential as, or are shorted with, terminal COM. 
* They are disabled unless pattern select is set up for terminal 

control using condition data. 

Common terminal for external control. (It has the same potential 
as input LO.) 

Start/Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM.

Peak Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM. 

Digital Zero terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM. 
* This terminal is disabled unless digital zero is set up for 
terminal control using condition data. 

P1
P2
P3

ON

OFF

Pattern7

ON

ON

OFF

Pattern6

ON

OFF

Pattern5

ON

OFF

Pattern4

ON

OFF

OFF

Pattern3

OFF

ON

Pattern2

OFF

Pattern1

ON

Pattern8

Adaptable wire: AWG24 to AWG16

Collector output terminal of HH output photocoupler 

Common emitter terminal for HH and HI output photocouplers 

Collector output terminal of HI output photocoupler 

Collector output terminal of LO output photocoupler

Collector output terminal of LL output photocoupler

Emitter terminal of GO output photocoupler

Common emitter terminal for LO and LL output photocouplers

Collector output terminal of GO output photocoupler

Recommended torque : 0.18Nm

Term. 

No.

Name

Description

1-4

10

0

 1-8

5-8

9-12

13-16

17

18

19

20

21,22

26

NC

27,28

COM

29

HH c

Bit-1 to bit-8 outputs of BCD 10

0

 digit

* For models A7X1X-3 and -4, terminals 29 to 34 are NC. Connect nothing to these terminals.

Connect nothing to this terminal.

10

1

 1-8 

10

2

 1-8

10

3

 1-8

POL

OVER

PC

ENABLE

DG

30

HI c

31

GO c

32

LO c

33

LL c

34

eCOM

Collector output terminal of HI output photocoupler

Collector output terminal of GO output photocoupler

Collector output terminal of LO output photocoupler

Collector output terminal of LL output photocoupler

Photocoupler's common emitter terminal

Bit-1 to bit-8 outputs of BCD 10

1

 digit

Bit-1 to bit-8 outputs of BCD 10

2

 digit

Bit-1 to bit-8 outputs of BCD 10

3

 digit

BCD polarity output

Collector output terminal of HH output photocoupler

Common terminal for external control. (It has the same potential as input LO.)

BCD overrange warning output

BCD printout command output

Common terminal for BCD outputs

EN

AB

LE

34

33

e

.C

O

M

L

O

 C

H

C

C

O

M

(N

C

)

 L

L

 C

G

O

 C

H

H

 C

C

O

M

D

Z

S

/H

D

G

P

C

P

O

L

P

H

D

G

O

V

E

R

2

1

10

2 8 2 8 2 8 2 8

1 4 1 4 1 4 1 4

0

10

1

10

2

10

3

10

0

10

1

10

2

10

3

23

S/H

Start/Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM.

24

PH

Peak Hold terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM.

25

DZ

Digital Zero terminal. Enabled when it has the same potential as, 
or is shorted with, terminal COM. 
* This terminal is disabled unless digital zero is set up for 
terminal control using condition data.

BCD enable terminal. BCD output becomes high impedance or 
transistor is turned OFF when this terminal has the same 
potential as, or is shorted with, terminal DG.

BCD Connector :
       HIF-3BA-34PA-2.54DS
Attachment Connector :
       HIF-3BA-34D-2.54R

* In the A7000 series, the range of use needs to be set using scaling data. 

  The unit is set to the thermocouple's KA ranges at factory shipment.

Burnout warning

Thermocouple : 

B.OUT

 is displayed in case of a break in TC HI or TC LO

                              RTD : 

OVER

 is displayed in case of a break in RTD A or RTD B

                                        

B.OUT

 is displayed in case of a break in RTD C

Note : Analog output produced in the event of burnout becomes minimal during B.OUT display or 

becomes maximal during OVER display. 

Description

Resistance element conductor connection terminal

Thermocouple's negative leg connection terminal

Thermocouple's positive leg connectuin terminal

Connect nothing to this terminal.

Connection terminal of a conductor resistance rejection wire

Resistance element conductor connection terminal

Applicable crimp terminal

5.8 or less 

5.8 or less 

Terminal 

No.

1
2
3
4
5
6

Name

TC HI

TC LO

NC

RTD A
RTD B
RTD C

Recommended torque : 0.5Nm

Summary of Contents for A7X18-X

Page 1: ...ice 4 Every effort has been made to ensure accuracy in the presentation of this manual However should you have any questions or should any errors or omissions come to your attention please contact you...

Page 2: ...oupler Collector output terminal of LO output photocoupler Collector output terminal of LL output photocoupler Emitter terminal of GO output photocoupler Common emitter terminal for LO and LL output p...

Page 3: ...terminal of HH output photocoupler Start Hold terminal Enabled when it has the same potential as or is shorted with terminal COM Peak Hold terminal Enabled when it has the same potential as or is sho...

Page 4: ...16 32 Large filtering effect Selects a display change width to limit variations in display If this parameter is set to 5 the least significant digit displays only 0 or 5 Selects display color Only wh...

Page 5: ...log output is provided Unit of temperature indication is set Main Setting Target and Precautions Setsthelowlimit of thedisplayablerange Avaluelower thanthedigital limiter LOsetpoint isnot updatedandis...

Page 6: ...ed returning the display to DLHI Condition data Measurement operation Pressing for a prolonged time Comparator data Scaling data Shift data Pressing the Enter key causes the instrument to store data a...

Page 7: ...an example of setting the tolerance judgment type in the next subsection Press the Increment key several times to move to the comparator data menu Press the Mode key to display comparison output type...

Page 8: ...press the Mode key the comparison output type setting content appears O U high and low limit judgment Err tolerance judgment Press the Increment key several times to move to the comparator data menu...

Page 9: ...s have the same potential 6 5 Digital Zero Function The digital zero function regards display at any timing as zero and indicates varying width from this point on This function can be activated or dea...

Page 10: ...measurement PC width depends on sampling Output logic Switchable PC logic not switchable Output signal TTL level fan out 2 COMS compatible Open collector output NPN type Measured data Transistor ON wh...

Page 11: ...he value in the table on the left 4 Comparison output delay time Relay output 10 ms maximum photocoupler output 200 s maximum Approx 4 8 s Approx 1 92 s Approx 96 ms Approx 192 ms Approx 384 ms Approx...

Page 12: ...D converter input or that power ON delay time is valid The zero point of contact compensation circuit is an unstable state temporarily It returns automatically by the sampling of several times Indica...

Reviews: