. Slide second clamp ring loosely over Hush Cushion

®

and up to previously tightened clamp ring. Do not tighten.

5

. Unscrew legs until there is a space of approximately 1/4” between the top of the upper housing and the Hush Cushion

®

. Raise disposer until

the upper housing slides into the Hush Cushion

®

.

Slide the loose clamp ring between the two lower beads on the Hush Cushion

®

and tighten.

6

. Assemble swirl spray or swirl sprays as shown in Figure 8. The method of assembly of the swirl sprays is typical. Other combinations of con-

vertible and fixed swirl sprays are available. The outlet hole of fixed spray head should be horizontal to promote swirling action in cone sink.
(convertible spray see Figure 9.)

7

. Connect copper tube or tubes to swirl sprays and bend in gradual curve to connect to fittings in valves. See Figure 7.

8

. Thread special nipple into drain outlet, slide hush connector over pipe and assemble and tighten clamp ring in two grooves.

NOTE: ALL PLUMBING AND ELECTRICAL CONNECTIONS SHOULD BE MADE ACCORDING TO LOCAL CODES

.

INSTALLATION DIMENSIONS AND DRAINLINE CONNECTIONS

FIG. 7

NOTE:

A globe valve used for metering flow to prevent solenoid
hammering must be installed between solenoid valve and
disposer. See Fig. 7. Any valve ahead of the solenoid valve
must be opened and cause no restrictions.

IMPORTANT! Do not test or run disposer without 

mini-

mum water flow

(see Plumbing Installation) as this will

damage the seal and void the warranty.

NOTE:

Disposer assembly includes disposer, outlet, nipple, Hush
Cushion

®

, clamps and supporting legs. Other items must be

purchased separately.

Items shown in gray in Figure 7 are

available in equipment groups ordered separately

.

#9T SPRAY RINSE
(Dotted Outline Illustates 9T Rinse)

MAGNETIC SWITCH
AND REMOTE
PUSH BUTTON
STATION

SYPHON
BREAKER
(Check Local
Code)

1" MIN.
ABOVE
TABLE RIM

1/2" GLOBE
VALVE FOR
METERING*

POWER
SUPPLY

SOLENOID VALVE

1/2" GLOBE VALVE

GATE VALVE

WASTE LINE

3/4" COLD WATER

GATE VALVE
1/2" HOT WATER

SEE FIG. 11

1/2" GLOVE
VALVE

TUBE

CLAMP
RING

MANUAL
SWITCH

ELBOW
TUBE FITTING

HUSH CUSHION

¤

APPROX. 40"

HOT WATER

FIG. 8

FIG. 9 CONVERTIBLE SPRAY

AERATOR SPRAY

SPRAY GASKETS

STEEL WASHER

CONICAL –
BRASS WASHERS

NUT

LOCK 

NUT

CONICAL
WASHER

TUBING

LOCK 
NUT

TUBING

NUT

STEEL WASHER

SPRAY HEAD

BRASS
WASHERS

SPRAY HEAD

GASKET

The convertible spray
should be located
opposite the direction
of travel of dishes in
scrapping operation.

FIG. 10

FIG. 11

DIMENSIONS

2000-1

2000-3

3000-3

5000-3

5000-38

10000-3

A

32

3

/

8 - 

35

1

/

8

32

3

/

8 - 

35

1

/

8

32

3

/

8 - 

35

1

/

8

32

7

/

8 - 

35

3

/

8

32

61

/

64 - 

35

29

/

64

32

61

/

64 - 

35

29

/

64

B

21

5

/

16

20

9

/

16

22

15

/

32

22

1

/

2

22

37

/

64

23

37

/

64

C

6

5

/

8

6

5

/

8

6

5

/

8

6

5

/

8

6

5

/

8

6

5

/

8

D

6

6

6

6

8

8

E

16

1

/

4

16

1

/

4

17

15

/

16

17

19

/

64

17

3

/

8

17

3

/

8

F

16

16

16

1

/

8

16

5

/

8

16

23

/

32

16

23

/

32

G

25

3

/

4 - 

28

1

/

2

25

3

/

4 - 

28

1

/

2

25

3

/

4 - 

28

1

/

2

26

1

/

4 - 

28

3

/

4

26

21

/

64 - 

28

53

/

64

26

21

/

64 - 

28

53

/

64

H

5

1

/

8

5

1

/

8

6

7

/

8

8

7

/

16

8

7

/

16

8

7

/

16

J

5

3

/

4

5

3

/

4

8

7

/

8

8

8

8

K

2

5

/

8

2

5

/

8

3

3

/

8

4

3

/

4

4

3

/

4

4

3

/

4

L

6

7

/

16

6

7

/

16

7

13

/

16

10

13

/

16

10

13

/

16

10

13

/

16

*

*

TRAP

WALL

DISPOSER

If space between dis-
poser and wall is
insufficient to allow
for installation of trap,
waste line may have
to be at an angle to
the wall as shown.

J

K

H

E

F

A*

G*

B

C

G minus B

D

Water

Inlet

Drain

Slope =
1/4” Per
Foot

L

Sink 
Flange

*

Legs are adjustable beyond the minimum shown in the screw adjustment. 2” clearance must be maintained beneath unit for proper ventillation.

Summary of Contents for 2000

Page 1: ...die pierces the stainless steel leaving a clean opening of 7 8 4 Place body valve and base in position assemble washer and locknut as shown in Figure 5 5 Attach vol temp assembly to the projecting ni...

Page 2: ...ms must be purchased separately Items shown in gray in Figure 7 are available in equipment groups ordered separately 9T SPRAY RINSE Dotted Outline Illustates 9T Rinse MAGNETIC SWITCH AND REMOTE PUSH B...

Page 3: ...piping connections d Where swirl spray fittings connect 2 After plumbing and electrical connections are made turn on disposer to be sure all parts are in working order and that the disposer turntable...

Page 4: ...erload protection NOTES 1 Motor wired at Factory for 208 240 volts For 460 volts connect motor wires as shown inside of motor junction box cover 2 Interchange T1 and T3 to reverse rota tion 3 Magnetic...

Page 5: ...l start when START button or Switch is pushed 5 If the motor hums and the turntable does not revolve freely there is usually an obstruction PUSH STOP BUTTON or Switch With a suitable bar or stick pry...

Page 6: ...AND F RESISTANCE TO DISTORTION AT TEMPERATURES TO WHICH THE ENCLOSURE MAY BE SUBJECTED UNDER CONDITIONS OF NORMAL OR ABNORMAL USE FOR A NON METALLIC ENCLOSURE ALL OF THESE FACTORS ARE TO BE CONSIDERE...

Page 7: ...MODELS 2000 1 2000 3 and 3000 3 DISPOSER LEG ADJUSTMENT AND MODIFICATION INSTRUCTIONS 560P304P01 REV A 3 0 76mm ADJUSTMENT MAX TOE UPPER LEG GLIDE 1 0 25mm BEFORE INSTALLING READ ENTIRE INSTRUCTIONS...

Page 8: ...FICATION INSTRUCTIONS 560P304P02 REV A BEFORE INSTALLING READ ENTIRE INSTRUCTIONS CAREFULLY 4240 E La Palma Avenue Anaheim CA 92807 800 454 4423 MODIFICATION PROCEDURE 1 Remove the plastic glide from...

Page 9: ...xpiration date of the original purchaser s warranty period This warranty shall not apply if service is provided by anyone other than a Factory Authorized Service Agency Nor will the warranty apply to...

Page 10: ...comply with our installation instructions or local building codes This warranty is for products purchased and retained outside of the United States of America the District of Columbia and Canada HOW...

Reviews: