background image

         

Pictogram for the Sequence in Time and Date Function

         

Choice of Working Mode

Defines whether the time should start immediately or once the heating value has been 

reached.

(a) (Default) Unit heats up to the temperature programmed via         taking into account 

any heat losses caused by the conveying pump. After reaching this value, the result 

measured is validated by a control cycle. If the value is confirmed, the polymerzation will 

start.

(b) The programmed polymerization starts immediately, but the earliest at 

65 °C

 Celsius. 

Please select a suitable preheating temperature         (see page 13.)

17

14

13

a

b

5

7

Summary of Contents for Wapo-Ex 8 plus

Page 1: ...Boil Out and Polymerisation Unit Wapo Ex 8 plus MANUAL ...

Page 2: ...revent accidents as well as the precautions given in this user manual We are not liable for any damages which occur due to inappropriate usage or faulty operation of this device Make sure that anyone using this device has read and understood this user manual Keep this user manual in a safe place where it can be referred to as required at any time The unit complies with the relevant EU guidelines T...

Page 3: ...Operation 18 8 1 General Operating Instructions 18 8 2 Boiling Out Operation 20 8 3 Hand Shower 20 8 4 Polymerisation Operation 21 9 Troubleshooting 22 10 Maintenance 23 10 1 Cleaning 23 10 2 Servicing 24 10 3 Repairs 24 10 4 Spare Parts 24 10 5 Service Hotline 0049 0 40 730 926 20 24 24 10 6 Scope of Delivery Accessories 24 11 Technical Data 25 12 Disposing of the Unit 26 12 1 Information on Disp...

Page 4: ...manual scalding Integrated hand spray made of non conductive plastic lowered lid and all round splash protection made of stainless steel Easy to clean without tools Designed for long durability High quality construction most parts made of stainless steel Energy saving thermal insulation 2 Application The Wapo Ex 8 plus is suitable for automatic boiling out or for the water bath polymerisation of u...

Page 5: ...tions in this user manual The equipment is designed only for its intended application WARNING Servicing and repairs should be carried out only by authorised specialists Disconnect the power plug before starting any maintenance work Make sure that the equipment is connected to the correct power source Attention Danger of Scalding Do not touch the hand shower at the nozzle or hose Do not point the s...

Page 6: ...ended by these instructions 5 1 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our service department Your equipment should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed This warranty ...

Page 7: ...water overflow discharge system i e too much filled very hot water runs out automatically even when the discharge cock is closed Furthermore complete emptying for cleaning purposes etc is thus simplified Avoid overfilling and check the overflow system drainage system Strong overfilling can damage the electronics in the medium term For damage caused by improper handling no liability is assumed 6 3 ...

Page 8: ... and the mains network is identical The filter mat is already placed with the white side facing down Fill the unit with water and Wachs Ex up to the overflow limit 21 litres max Dosage approx 45 ml 21 litres water Switch on the mainswitch green rocker switch Symbol water deficit must not appear Also avoid an overflow Water deficit Make sure you define the device s main parameters before switching ...

Page 9: ...The Set Up Menu Title Actual temperature To the set up menu Heating On Off Polymerisation menu Boil out menu 9 3 2 4 6 5 1 ...

Page 10: ...s in the set up menu Start temperature Timer Continue in the menu Sleep Calibration method Back to start menu The Set Up Menu Page 2 C F Date and time Continue in the menu Work mode Information Back to the start menu 10 8 9 11 13 9 15 7 10 12 14 16 16 ...

Page 11: ...ouching the boil out symbol once again To relieve the hose and hand shower of pressure when not in use the ball cock should always be returned to the horizontal basic position Automatic Boil Out Menu Ball cock basic position lever horizontal Here you can set the temperature and the time for the boil out process By tapping the numbers increases and the values can then be changed Press the Start but...

Page 12: ...uch the numbers to change the values It is possible to store up to three polymerization steps 1 3 Polymerization Step 1 Delete To the next program Save Examples of the Steps 2 and 3 Start Touch the arrow to start the polymerization Interrupt or cancel the program using Start Stop 12 6b ...

Page 13: ...ture selected is higher the temperature falls back to this value when the programme ends After defining the desired mode it may make sense to adjust the preheat temperature of the programme temperature This avoids long heating up or cooling down phases The preheating temperature can be up to 8 C higher than the program temperature so that the program can run The controller will then adjust reduce ...

Page 14: ...he weekday activation and deactivation times Programs running currently have a higher priority they are not switched off until complete Sleep Button Display Press the Sleep button to switch the system to sleep mode 14 8 10 ...

Page 15: ...f Calibration Method DEF Default calibrated for mains water CAL Calibration only necessary for extreme deviations in water quality This measure defines the conductance of the water Drain water Replenish water 15 11 ...

Page 16: ...can be set in the range of 9 9 to 9 9 Calibrate the temperature with an absolute offset 0 0 C To correct the heater curve by a value in C or F you can use the absolute offset of the heater curve As shown in the symbol the zero crossing of the heating characteristic shifts when this value is changed The absolute offset value can be set in the range of 9 9 C to 9 9 C 16 12 12b Change the value and t...

Page 17: ... to the temperature programmed via taking into account any heat losses caused by the conveying pump After reaching this value the result measured is validated by a control cycle If the value is confirmed the polymerzation will start b The programmed polymerization starts immediately but the earliest at 65 C Celsius Please select a suitable preheating temperature see page 13 17 14 13 a b 5 7 ...

Page 18: ...ng from burning out flashing symbol While the program is running an alarm sounds when there is insufficient water Take care that the water level is always above the white plastic ring see in the housing as the heating and the program will otherwise shut down automatically An additional safeguard protects the heating against overheating it is automatically deactivated at above 97 C Avoid overfillin...

Page 19: ...only use the hand shower in the area of the screen cover or the hand basin During boiling out with the hand shower you must shift the ball cock situated at the right side at the top of the housing to the vertical position To relieve the hose and hand shower of pressure when not in use the ball cock should always be returned to the horizontal basic position Unplug the device if it is not in use for...

Page 20: ...eset temperature again see page 13 For the manual boil out process the ball cock must be returned to the vertical position Than the manual boil out process is initiated by touching the boil out symbol To stop the process touch the boil out symbol once again 8 3 Hand Shower In its ready state 65 C you can activate the hand shower at any time by moving the ball cock to the vertical position The sett...

Page 21: ...cker switch Check the water level the low water alarm must not flash Place prepared cuvettes in the device clamp The polymerization is started by touching the symbol or alternatively via the parameter menu fter the polymerations process has ended the temperature falls rises to the preset temperature again see page 13 21 A 6b 6a 7 Water level sensor 6b A 6a 7 ...

Page 22: ...he touch display Turn the unit on and while the Wassermann logo appears tap the touch display twice This will take you to the self explanatory touch panel calibration process Fig 2 3 Programme not starting although set temperature has been reached In mode a the unit intentionally overheats by 1 C and waits briefly to validate the value This is not a fault please wait roughly 45 sec If the above re...

Page 23: ...ation Once a week Change water and add Wachs Ex Dosage approx 45 ml 21 litres water Clean the level tracer white plastic ring i e with a nail brush Every 2 weeks Replace the filter mat white side facing down Every 4 weeks Clean the unit with Kalk Ex Dosage approx 300ccm Kalk Ex per full tank 21 litres water If there is considerable limescale present increase the amount of Kalk Ex appropriately The...

Page 24: ...er it or if inappropriate components are installed 10 4 Spare Parts If necessary please contact our service hotline phone 10 5 Service Hotline 0049 0 40 730 926 20 24 10 6 Scope of Delivery Accessories Included in delivery Service set 4 filter mats 1 L lime remover 2 L wax remover Discharge hose 1 5 m Hose clip Ø 20 32 x 12 2 Accessories Item no Mobile stand W 620 x H 550 x D 430 mm 170120 Service...

Page 25: ...50 60 Hz Power consumption 9 A Output 2000 W W x H x D max W x H x D housing 660 x 585 x 480 mm 615 x 550 x 425 mm Weight 41 kg Noise emission 70 dB A Capacity 21 l Other voltages on request The noise level of the unit amounts to 70 dB A Technical changes reserved 25 ...

Page 26: ...otect the environment prevent environmental pollution and improve the recycling of raw materials the European Commission adopted a directive that requires the manufacturer to accept the return of electrical and electronic units for proper disposal or recycling Within the European Union units with this symbol should not therefore be disposed of in unsorted domestic waste For more information regard...

Page 27: ...dert wird This is to confirm that the above mentioned machine complies with the described EU guidelines This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur d Union européenne Cet avis est nul et non avenant si cette machine est modifiée sans notre accord Esta máquina anteriormente mencionada cumple con los limites requer...

Page 28: ......

Reviews: