AIRCUT
-101
I
,161
IW
,200
IW Inverter Plasma Cutting Machine
WARPP ENGINEERS PVT LTD
22
12
、
Operation
1)
Safety notes
Notes:
Operation strictly accordant with the following steps
Notice
Electric shock may
hurt or even kill man.
Cutting may cause fire or explosion
(Splashes may ignite flammable materials
nearby. Those materials should be 10m away
from the working place.
(Shutoffthe powerduring
connection
(Donot touchthe conductedparts
Fume & dust is harmful.
(Do not breathe in the fume and
dust caused by cutting
(Clean up the oil spot on work
piece.
(Keep fresh air in working place
(Fume extraction equipment
should be prepared.
Arc may hurt your eyes and skin.
(Strong arc may hurt your eyes.
(Ultraviolet radiation generated by arc may
hurt skin and eyes. Please wear shielded
guard when cutting.
Overheated part may hurt your
skin.
(Donottouchtheoverheatedpart
on the work piece.
(Do not touch hot cable or torch
just by hands.
Fast moving thing may injure you.
(Do not put your hands or other things into
the fan shield.
(Cover the opened case shell well during
cutting operation.
In case of injury foryourskinandeyes, please wear required
guards according to Labor Security and Hygiene rules. Electrode
andnozzle should bereplacedonlyafterthe cutteris poweroff.
Operation should proceed according to related Labor and
Security regulations.
2)
Turn on the power switch after installation and connection. Then the power
indicator lamp isON;
3)
Start gas supply equipment and turn on the gas supply switch, the power indicator
lamp on the panel is ON. If the gas pressure is less than 0.25Mpa, the lamp will be
OFF, then the gas source should be checked;
4)
Startwater supply equipment. Theindicator lamp ofwater pressure on panel is ON
whenopenswatersupplyvalve. (AIRCUT-101 I does nothavethisfunction)