Cross Corner
B
Flush with Wall
C
Flat on Wall Corner
D
Flat on Wall
E
Island
F
Room Divider
15 ft Max.
15 ft Max.
INSTALLATION INSTRUCTIONS
PRECAUTIONS
•
This appliance must be installed by a qualified gas installer and the installation conform to the
installation codes.
•
Provide adequate clearance around air openings of the appliance. Never obstruct front openings.
•
Provide adequate clearances for proper operation and servicing of the appliance.
•
This appliance must be properly connected to a venting system.
5
LOCATING GAS FIREPLACE
This appliance must be installed in any location that is free of plumbing, electrical wiring and heating or
air conditioning ducts. Select a location that is accessible for venting. See APPENDIX A.
ALLOWABLE TERMINATION LOCATIONS.
VENT TERMINATION
1. See “ALLOWABLE TERMINATION LOCATIONS” diagram (page 24) to establish a suitable vent
termination location.
2. In heavy snowfall areas make sure vent termination is located where it can not be blocked by snow or
snow from snow removal equipment.
3. Locate vent termination away from plants, bushes or any other object on or near the vent termination
that will interfere or obstruct the air flow around it.
4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7ft from grade level or anywhere it can be a burn hazard to the public,
such as patios and balconies, must be protected with an Archgard approved termination cage.
6. Always ensure bottom of Vent Terminal is a minimum of 12” above grade.
*NOTE: Rear vented gas fireplace DVR36H can only be located in positions
A, B, C and D.