background image

Warner Electric • 800-825-9050

P-2101-WE • CBCx-001 

  

3

General information

Power supply enclosure should be kept clear of all 
areas where foreign material, dust, grease, or all 
might affect the operation of the control.

Installation must be made in accordance with the 
instructions found in this manual. Failure to do so 
may damage the Power supply.

Electrical Connection

1

DC BRAKE +

Power Output

Output contact to the Clutch/Brake Coil. DC Power output : 90 VDC to 450 VDC.

2

DC BRAKE -

Power Output

Output contact to the Clutch/Brake Coil.

3

SHUNT+

Accessory

Current Sensing.
Contact which allows the opening of the power supply DC Side to integrate a current 

sensing or over measuring instrument. One can add a Hall effect current probe for 
instance.

Default : When not used, a Short circuit bridge is needed between pins 3 and 4.

4

SHUNT-

Accessory

Current Sensing.

5

DC

Accessory

DC switching off.
Use to Power off the brake with a Fast Response Time : Emergency stop for 

instance.

Default : When not used, a Short circuit bridge is needed between pins 5 and 6.

6

DC SWITCH -

Accessory

DC switching off.

7

AC

Power Input

AC power Input : 90VAC to 500VAC

8

AC

Power Input

AC power Input : 90VAC to 500VAC

9

PE

Protective Earth

This terminal is usually connected to earth provided by the AC grid.

Logical 

Control 

1

ON/OFF +

Digital input

Logic Control. 24V PNP input. When High, powers up the brake. This power up will 

be made on the AC side, with offering

If over-excitation feature is enabled, then over-excitation voltage is applied during the 

programmed time.

Active High/GND: PNP type Input.

Logical 

Control 

2

Ground

Digital input

Ground