Warner Electric • 800-825-9050

P-2101-WE • CBCx-001 

  

5

DIP Switch selection

+

1 2

3

4

5 6

7 8

OFF

ON

LOGIC CONTROL

DIP SWITCH

24VDC

+

-

DIP1

if ON          PNP Logic control input 

disabled

DIP2

if ON          Full Wave 

forcing

 

If ON, Over-excitation is always enabled.

DIP3

if ON          Over-excitation 

Disabled

50ms 100ms 150ms 500ms 1000ms 

(Default)

1500ms 2000ms 3000ms 4000ms

DIP4

ON

ON

ON

ON

ON

ON

ON

DIP5

ON

ON

ON

ON

ON

DIP6

ON

ON

ON

ON

DIP7

ON

ON

ON

ON

ON

ON

DIP8

Not used

Examples

AC switching with external contactor

 (not supplied) 

/ 24VDC PNP Control not used / 1s Over-excitation:

DIP1

:

ON

DIP2

:

OFF

DIP3

:

OFF

DIP4:

ON

DIP5:

ON

DIP6:

OFF

DIP7:

ON

24VDC PNP Control Enabled / 500ms Over-excitation:

DIP1

:

OFF

DIP2

:

OFF

DIP3

:

OFF

DIP4:

ON

DIP5:

ON

DIP6:

ON

DIP7:

ON

AC switching with external contactor 

(not supplied) 

/ 24VDC PNP Control not used /  

Full wave control (no Over-excitation):

DIP1

:

ON

DIP2

:

ON

DIP3

:

NA

DIP4:

NA

DIP5:

NA

DIP6:

NA

DIP7:

NA

AC switching with external contactor 

(not supplied)

 / 24VDC PNP Control not used / Half wave control :

DIP1

:

ON

DIP2

:

OFF

DIP3

:

ON

DIP4:

NA

DIP5:

NA

DIP6:

NA

DIP7:

NA

Installation

1

DC BRAKE +

2

DC BRAKE -

3

SHUNT+

4

SHUNT-

5

DC

6

DC SWITCH -

7

AC

8

AC

9

PE

Brake

Measuring loop

- If not used, please Short Circuit 3 & 4 -

Fast Response time Switch OFF.

- If not used, please Short Circuit 5 & 6 -

Protective circuit

(FF 5 Amps)

Connected to the Grid

100 VAC to 500 VAC (+/- 10%)

50 – 60 Hz