Technical Data

Input Voltage

100 VAC to 500 VAC (+/- 10%) 50 – 60 Hz

Output Voltage

90 VDC to 450 VDC

With Over-excitation

U

Brake

 (VDC) = 0,9 x U

AC

   (Limited to the selected over-excitation time)

Full Wave

U

Brake

 (VDC) = 0,9 x U

AC

Half Wave (Holding voltage) U

Brake

 (VDC) = 0,45 x U

AC

Max T °C

Output Current

70°C

2 Amps Over-excitation (double Wave) / 1 Amps Holding (Single Wave)

60°C

3 Amps Over-excitation (double Wave) / 1.5 Amps Holding (Single Wave)

50°C

5 Amps Over-excitation (double Wave) / 2.5 Amps Holding (Single Wave)

AC Input:

100 to 500 VAC

On/Off Switch

(AC Side)

Output

Voltage suppression

Over-Excitation

DIP4-7

: Programmable Over-Excitation Time:

50ms to 4000ms.

DIP3

: Diable

Full Wave

DIP2

: Enable

Bridge Rectifier

DC Switch OFF

Shunt

Logic Control

(PNP type)

DIP1: Disable

!

!