Programmable Thermostat WA-XSTAT

INSTRUCTIONS

English

The electronic comfort controller is a clock

thermostat that can be programmed to function

as a floor temperature controller and room

temperature controller with a limitation function.

The thermostat is intended for mounting in a 

55 mm standard wall socket. The operating area

ranges from +0° to +30°C. The thermostat

incorporates a clock enabling the programming

of several setback functions.

Controller setting WA-XSTAT
Program choice:

Floor temperature control
Floor temperature control with 2 sensors
Air temperature control
Air temperature control with floor 

temperature limit
Regulator control
External control

The controller is designed in accordance

with current product standard EN 60730-

2-9, and fulfill hereby the requirements to both

LVD and EMC directives.

The controller must not be put into operation

until it has been ascertained that the entire

installation complies with current general safety

requirements for electrical installations. 

The warranty is only valid if the controller has

been put into operation in accordance with the

operating instructions supplied with the

controller and these installation instructions. 

Technical data

Supply voltage  . . . . . . . . . . .230V ±15%, 50 Hz

Output relay SPST . . . . . . . . . . . . . .16A, 3600W

Temperature range  . . . . . . . . . . . . . . . .+0/+30˚C

Temperature limitation   . . . .min./max. +5/+55˚C

Clock function  . . . .1 pre-installed programmes

28 optional setback programmes

Ambient temperature  . . . . . . . . . . . . . . .0/+30˚C

On/off differential  . . . . . . . . . . . . . . . . . . . .0,4˚C

Housing  . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 21

Sensor type  . . . . . . . . . . . . . . . . . . . . . . . . .NTC

- heating is switched off in case of sensor failure

Dimensions (HxWxD) (fig. 6)  . . . . .86/86/48 mm

The controller is maintenance-free.

Control pollution degree: 2

Pollution degree 2 is representative of normal

household air circulation.

Overvoltage category: III

Classification

The product is a class II device (reinforced

insulation) and the product must be connected

to the following conductors:

1) Phase (L)

2) Neutral (N)

The thermostat is constructed to store the clock

up to 4 hours at an occasional voltage

interruption. It is not suitable for use by regular

voltage interruptions. (Example: Power term

applications). At such conditions a constant

power supply for the thermostat must be

ensured.

WARNING – Important Safety Instructions

Isolate supply before carrying out any

installation or maintenance work on this control

unit and associated components. This control

unit and associated components should only be

installed by a competent person (i, e qualified

electrician). Electrical installation to be in

accordance with latest IEE Wiring Regulations

and appropriate Statutory Regulations. 

Mounting of sensor

Floor sensor: 

Placed in an approved non

conductive installation pipe in accordance with

EN 61386-1, which is embedded in the floor.

(fig. 3). The pipe is closed in the end and placed

as high as possible in the concrete layer. The

installation pipe must be centered in between

the heating cable.

The enclosed 3 meter sensor cable can be

extended up to 100 m by means of a separate

cable. If the extension cable is lighter than

H05VV-F, it shall equally be installed in an

unbroken installation pipe between the sensor

cable and the extension cable. Two remaining

cores of a multi-core cable which, for example,

supplies current to the heating wires of a floor

heating system, must not be used. The

switching peaks of such current supply lines

may create interfering signals that prevent

optimum controller function. The two-corecable

must be placed in a separate pipe.

Controller installation site

The controller must be mounted on the wall so

that air can circulate freely around it (fig. 4). An

installation site must be selected where the

controller is not exposed to foreign energy

sources, e.g. solar radiation. The controller must

not be exposed to draughts coming from, for

example, windows, doors or cold outer walls. 

The controller has a built-in fault interrupter

circuit which interrupts the heating in case of

disconnected or short-circuited sensor.

Mounting of controller 

The  single gang mounting box must have a

debt of no less than 25 mm.

1. Use a screwdriver in both sides to open the

lock.

The cover must be dismounted (fig. 1).

2. 

Connect cables according to the diagram

(fig. 2a-2b).

All electrical connections must be performed by

a fully qualified and Part P certified electrician.

3. The thermostat is mounted in the wall 

socket. The cover is remounted.

Programming

(See user manual)

The controllers are delivered with a pre-installed

setback programme.

If the pre-installed setback programme is not

used, there are different programmes which can

be selected and used on the required days.

The controllers calculate when the heating is to

be switched on to make sure that the comfort

temperature is obtained to the required time.

Fault location

If the sensor is disconnected or short-

circuited, the heating system is switched off.

The sensor can be checked according to the 

resistance table fig. 5.

Environment and recycling

Please help us to protect the environment by

disposing of the packaging in accordance with

the national regulations for waste processing. 

Recycling of obsolete appliances

Appliances with this label must not

be disposed off with the general

waste. They must be collected

separately and disposed off

according to local regulations.

Warmup Plc

702 Tudor Estate · Abbey Road

London NW10 7UW

T. +44 845 345 2288

F. +44 845 345 2299

warmup.com

Español

El controlador electrónico de confort es un

termostato cronometrado que se puede

programar para funcionar como controlador de

temperatura del piso y como controlador de

temperatura ambiente con una función

limitadora.

El termostato está diseñado para montaje en un

receptáculo de pared estándar de 55 mm. Los

límites de funcionamiento son de 0° a +30 °C.

El termostato incorpora un reloj que permite la

programación de varias funciones de reducción

de temperatura.

Ajuste de controlador WA-XSTAT

Opción de programa:

Control de temperatura de piso
Control de temperatura de piso con 2 

sensores
Control de temperatura del aire
Control de temperatura del aire con límites 

de temperatura de piso
Control regulador
Control externo

El controlador está diseñado de acuerdo

con las normativas de producto vigentes

EN 60730-2-9, y por lo tanto cumple los

requisitos de las directivas LVD y EMC.

No se debe accionar el controlador antes de

verificar que toda la instalación cumpla con los

requisitos vigentes de seguridad general para

instalaciones eléctricas.

La garantía es válida solamente si el controlador

se ha puesto en servicio de acuerdo con las

instrucciones de operación suministradas con

el controlador y estas instrucciones de

instalación.

Datos técnicos

Tensión de alimentación   . . .230 V ±15%, 50 Hz

Relé de salida SPST  . . . . . . . . . . .16 A, 3600 W

Rango de temperatura  . . . . . . . . . . . .+0/+30 °C

Limitación de temperatura mín./máx. +5/+55 °C

Type WA-XSTAT

57627B 11/06 (BJ)

NW107UW-A

Summary of Contents for WA-TSTAT-V

Page 1: ... Unless you change these settings the thermostat will operate to this default program Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set After 3 days ...

Page 2: ...Home and for the Weekend Day and Weekend Night Moreover you can define when you want each time period Day Night Out Home Weekend Day and Weekend Night to begin Please note You need to use the Down button to move to the end of the menu Finally you can specify temperatures and periods Day Night Out Home for each day of the week Monday Tuesday Wednesday Thursday Friday Saturday and Sunday This requir...

Page 3: ...0 minutes If you for example set the regulator to 50 the thermostat will turn on for 10 minutes switch off for 10 minutes and then turn on again for 10 minutes External Control Used in case of a set up with several thermostats being controlled by an external master thermostat Then the thermostat will work as a slave and you cannot apply any settings at all since the master thermostat controls it 6...

Page 4: ...is not deleted though 7 Error Messages If you get an error the LED is flashing red Internal failure Contact Warmup External failure Contact Warmup Day 1 5 Event Time With floor sensor With air sensor Day 06 00 08 00 25 C 20 C Out 08 00 16 00 20 C 15 C Home 16 00 22 30 27 C 22 C Night 22 30 06 00 20 C 15 C Day 6 7 Event Time With floor sensor With air sensor Day 08 00 23 00 27 C 22 C Night 23 00 08...

Page 5: ... such current supply lines may create interfering signals that prevent optimum controller function The two corecable must be placed in a separate pipe Controller installation site The controller must be mounted on the wall so that air can circulate freely around it fig 4 An installation site must be selected where the controller is not exposed to foreign energy sources e g solar radiation The cont...

Page 6: ...ión del fallo Si el sensor está desconectado o en cortocircuito se apaga el sistema de calefacción Se debe verificar el sensor de acuerdo con la tabla de resistencias de la fig 5 Medio ambiente y reciclaje Por favor ayúdenos a proteger el medio ambiente mediante la eliminación del material de embalaje de acuerdo con las normativas nacionales para el procesamiento de desechos Reciclaje de electrodo...

Page 7: ...em dazu autorisierten Elektriker ausgeführt werden 3 Den Thermostat in der Wanddose montieren Der Deckel wieder aufsetzen Programmierung siehe Benutzerhandbuch Die Regler werden mit einem vorinstallierten Setback Programm geliefert Das vorinstallierte Setback Programm kann mit verschiedenen wahlweise zur Verfügung stehenden Programmen zur Anwendung an beliebigen Tagen ausgetauscht werden Die Regle...

Page 8: ...5 7 6 2 7 B BR929A04 1 6m Fig 4 Fig 5 Fig 6 Fig 1 Fig 2a With fil pilote Fig 2b Master slave function Fig 3 ...

Reviews: