background image

www.Warming-Trends.com  |  303 346 2224  |  [email protected]

20

MEDIA INSTALLATION

Only use approved decorative media (glass, lava rock, 

ceramic log sets, etc.) that have been manufactured for 

VSHFLƓFXVHLQƓUHIHDWXUHV

Media must be ½” or larger in size to prevent media from 

IDOOLQJLQWRJDVRULƓFHVDQGEORFNLQJŴRZRIJDVRXWRI

jets. Use approved media only. To avoid dust and clogs get-

ting into the system, do not dump the media over the burner. 

Place the media onto the plate or pan. 

Burner should be covered by approved media up to ½” 

above the jets. Media may be positioned so that jet tips or 

barrels are visible. PLEASE NOTE - covering jets by more 

than ½” of media may create back pressure and gas 

OHDNDJHUHVXOWLQJLQSRROLQJRIJDVXQGHUWKHƓUHIHDWXUH

ZKLFKFDQUHVXOWLQH[SORVLRQZKLFKFRXOGFDXVHSURSHU

-

ty damage, personal injury, or death.

$OVRQRWHWKDWŴDPH

pattern will be affected by any media coverage over gas 

RULƓFHMHWVXSWRDQGLQFOXGLQJVPRWKHULQJRIŴDPHV

When using electronic ignition systems please pay par-

ticular attention to keeping media away from the pilot 

assembly area and/or away from wind screen of pilot 

assembly. Incorrect media installation that blocks pilot 

DVVHPEO\ZLOOFDXVHWKHSLORWŴDPHWRVWLŴHEORFNLQJRI

thermal sensor and/or a delay in main burner ignition. 
The appliance is designed to use approved media that is 

correctly installed over the burner to achieve proper com-

bustion. Use of any media outside of the approved media 

may void warranty and affect proper operations.

,QVWDOOHQFORVXUHDQGƓUH

feature per instructions 

provided by manufacturer. 

DO NOT DUMP MEDIA 

ON THE JETS. Apply media 

by pouring media around 

EXUQHUƓUVWWKHQSXVKLQJ

media towards the gas jet 

RULƓFHVPDNLQJVXUHPHGLD

does not fall into the gas jet 

RULƓFHV&KHFNHDFKJDVMHW

RULƓFHSULRUWROLJKWLQJWREHVXUHQRPHGLDKDVIDOOHQLQWR

JDVMHWRULƓFHV

For All Electronic Ignition Systems: Keep pilot assembly 

screen free and clear of all media. Media should be piled no 

more than halfway up screen only (not over full amount of 

VFUHHQVRWKDWSLORWJDVRULƓFHRSHQLQJLVDERYHPHGLDFRY

-

HUDJHDOORZLQJIRUSLORWŴDPHWRHDVLO\UHDFKJDVMHWRULƓFH

For Ceramic Log Sets: 

Place logs on top of lava 

rock or media base ac-

cording to preference and 

GHVLUHGŴDPHSDWWHUQ)RU

electronic ignition systems 

- do not block, cover or 

obstruct pilot assembly. 

Blocking, covering or placing ceramic logs too close to 

pilot may cause excessive heat on pilot causing system to 

fail. This is not covered under warranty.

OPERATING INSTRUCTIONS

Keep the area clear and free from combustible materials, 

JDVROLQHDQGRWKHUŴDPPDEOHYDSRUVDQGOLTXLGV
6ROLGIXHOVVKDOOQRWEHEXUQHGLQWKHƓUHSLW/HDYHVVWLFNV

wood, paper, clothing, food material, should be kept away 

IURPWKHƓUHSLW0DNHVXUHWKDWWKHUHLVQRYHJHWDWLRQRU

RWKHUREMHFWVRYHUWKHWRSRUVLGHVRIWKHƓUHSLWWKDWFRXOG

interfere with safe operation. If there are any questions as 

to clearances, refer to CLEARANCES DIAGRAM in your 

,QVWDOODWLRQ0DQXDOIRUVSHFLƓFFOHDUDQFHDOORZDQFHV
:LQGDQGJXVW\FRQGLWLRQVPD\FDXVHWKHŴDPHWREH

-

have in an unpredictable manner. If conditions exist, turn 

RIIWKHƓUHIHDWXUH
$OOPHGLDODYDURFNYROFDQLFVWRQHƓUHJODVVHWFKDV

the potential of thermal spalling. This process may occur 

when media is wet and moisture gets trapped inside of 

the material due to rapid temperature differences. When 

this happens the media has the potential to crack or pop 

RXWVLGHRIWKHƓUHSODFH([WUDFDXWLRQVKRXOGEHWDNHQ

when lighting in high humidity or moisture. After igniting, 

allow 30 minutes to dry out the media, and monitor from 

a distance until all popping has ceased before fully enjoy-

LQJWKHƓUH

TURNING ON YOUR MATCH LIT SYSTEM 

1.  STOP! 

Read all the safety information.

2.  Any cover must be removed prior to operation of burn-

er or appliance and must remain off during operation. 

'DQJHU)LUHRU([D]DUG,I\RXVPHOOJDV

VKXWRIIJDVWRWKHDSSOLDQFHH[WLQJXLVKDQ\RSHQ

ŴDPH,IRGRUFRQWLQXHVOHDYHWKHDUHDLPPHGL

-

ately. After leaving the area, call your gas supplier 

RUƓUHGHSDUWPHQW)DLOXUHWRIROORZWKHVHLQVWUXF

-

WLRQVFRXOGUHVXOWLQƓUHRUH[SORVLRQZKLFKFRXOG

cause property damage, personal injury or death.

3. 

&RQƓUPWKDW\RXUPDLQ1DWXUDO*DVRU/LTXLG3URSDQH

supply to the appliance is open. 

Do not open your 

key valve or gas control valve at this time.

4. 

%HIRUHOLJKWLQJYLVXDOO\LQVSHFWƓUHIHDWXUHDQGUHPRYH

any accumulated leaves or other combustible debris.

5.  Locate key valve or gas control valve controlling gas 

supply to your appliance.

6.  Locate the closest jet tip on the exterior of the burner 

that can be easily accessed while operating key valve 

or gas control valve without reaching across other jets 

Summary of Contents for CROSSFIRE CFB60 NG

Page 1: ... Warming Trends V1 R5_03 20 2020 Owner s Guide and Instruction Manual Thank you for your purchase ...

Page 2: ...U H SORVLRQ ZKLFK FRXOG cause property damage personal injury or death WARNING R QRW VWRUH RU XVH JDVROLQH RU RWKHU Ŵ DPPDEOH YDSRUV DQG OLTXLGV LQ WKH vicinity of this or any other appliances An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoor Use Only QVWDOODWLRQ DQG VHUYLFH PXVW EH SHUIRUPHG E D TXDOLƓ HG LQVWDOOHU VHUYLFH ...

Page 3: ...XHU XQ LQFHQGLH RX XQH H SORVLRQ SRXYDQW FDXVHU GHV GRPPDJHV PDW ULHOV GHV EOHVVXUHV RX OD PRUW AVERTISSEMENT 1H SDV HQWUHSRVHU QL XWLOLVHU GH OōHVVHQFH QL GōDXWUHV YDSHXUV RX OLTXLGHV LQŴ DPPDEOHV GDQV OH YRLVLQDJH GH OōDSSDUHLO QL GH WRXW DXWUH DSSDUHLO 8QH ERXWHLOOH GH SURSDQH TXL QōHVW SDV UDFFRUG H HQ YXH GH VRQ XWLOLVDWLRQ QH GRLW pas être entreposée dans le voisinage de cet appareil ou de t...

Page 4: ... with P24VIKSC Model CFBL150 NG LP with P24VIKSC Model CFBL190 NG LP with P24VIKSC Model CFBL210 NG LP with P24VIKSC Model CFBL250 NG LP with P24VIKSC Model CFBL270 NG LP with P24VIKSC Model CFB60 2XL NG LP with P24VIKSC Model CFBH120 NG LP with P24VIKSC Model CFBH160 NG LP with P24VIKSC Model CFBH200 NG LP with P24VIKSC Model CFBH240 NG LP with P24VIKSC Model CFBH260 NG LP with P24VIKSC Model CFB...

Page 5: ...WKH SLW DQG FRXOG FDXVH ƓUH RU H SORVLRQ ZKLFK FRXOG FDXVH property damage personal injury or death WARNING Product is not intended to be used to burn wood or other combustibles Solid fuels shall not be burned in the appliance R QRW SXW DQ FRPEXVWLEOH PDWHULDOV LQWR WKH ƓUH SLW WARNING 2QO XVH LTXLG 3URSDQH RU 1DWXUDO DV DV VSHFLƓHG IRU RXU DUPLQJ 7UHQGVp DSSOLDQFH or burner Do not use an alternat...

Page 6: ...ry high temperatures combusti bles must be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate GLVWDQFH DZD IURP ŴDPH GXH WR ULVN RI FUDFNLQJ 0DQXIDFWXU er is not responsible for damage to any enclosure material for any reason FIRE PIT CLEARANCES 36 horizontally from any combustible s...

Page 7: ...ORZ IRU emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or EUHDNHU RQ WKH H WHULRU RI WKH DSSOLDQFH or on adjacent structure to allow for emergency shutdown and maintenance Verify correct power supply If located on the vessel key valve should be mounted below the plate and through the side wall of the vessel Key valves may b...

Page 8: ...5 For models that include electronic ignitions be sure to KDYH D TXDOLƓ HG HOHFWULFLDQ LQVWDOO SURSHU SRZHU VXSSO following all local codes 6 QVSHFW Ŵ H OLQH V IRU SXQFWXUHV RU EUHDNV LQ OLQH V 7 Make sure the key turns in the key valve before in stalling Use only your hand to turn the gas key valve Never use tools If the key valve will not turn by hand don t try to repair it Force or attempted re...

Page 9: ... do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 2QO XVH ƓUH UDWHG PHGLD JODVV ODYD URFN ORJ VHWV etc approved for use with high temperatures that KDYH EHHQ PDQXIDFWXUHG IRU VSHFLƓF XVH LQ ƓUH IHD tures Never use any material for media that is non po rous and holds moisture such as gravel pebbles river rock etc Such material when heated may cause the tr...

Page 10: ... ŴDUHG HQG RQ ERWWRP 7LJKWHQ 3A Connect to FIT180 then to Coupling FLKV34FIT180 Connect one Flared Fitting removed LQ 6WHS WR 7 ƓWWLQJ SURYLGHG E LQVHUWLQJ 7 LQWR LQWHULRU WKUHDGV RI WKH ODUHG LWWLQJ 7LJKWHQ Then connect WKH 7 ƓWWLQJ into the coupling located on the bottom of the aluminum plate Tighten 3 Key Escutcheon Key Valve FIT180 Kit x 2 Nipple Included with FLKV34FIT180 ONLY 12 Key STEP 1 F...

Page 11: ... to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line Key WALL GAS LINE IN FLKV12 SHOWN Escutcheon Plate Plate Coupling Flared Fitting Whistle Free Flex Line 5 Locate 2nd Flared Fitting and Connect to Key Valve FLKV12 and FLKV34FIT180 Locate the second Flared Fitt...

Page 12: ...ex Lines STEP 1 FIT250 STEP 1 FIT250 STEP 1 FIT250 5HPRYH ODUHG LWWLQJV IURP KLVWOH UHH OH LQHV 9 7 DQG 9 7 5HPRYLQJ ŴDUHG ƓWWLQJV ƓUVW PDNHV DWWDFKLQJ WR 7 RU 7 HDVLHU 3 Connect FIT250 to Coupling DFLKV34FIT250 Connect x Reducing Fitting to Coupling located on the bottom of the aluminum plate Then connect Tee to x Reducing Fitting 3A Connect FIT300 to Coupling DFLKV34FIT300 Connect x 3 Nipple to ...

Page 13: ... Flared Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall Tighten STEP 5 Plate Coupling FIT250 x Reducing Fitting or FIT300 x 3 Nipple FIT250 or FIT300 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here Key Valve FIT...

Page 14: ...x 2 Nipple Included with FLKV34FIT180 ONLY 12 Key STEP 1 FIT180 Whistle Free Flex Line 3 Connect to Coupling FLKV12 Connect one Flared Fittings removed in Step 2 to Gas Valve Plate 3A Connect to FIT180 then to Coupling FLKV34FIT180 Connect one Flared LWWLQJ UHPRYHG LQ 6WHS WR 7 ƓWWLQJ SURYLGHG E LQVHUWLQJ 7 LQWR LQWHULRU WKUHDGV RI WKH ODUHG LWWLQJ 7LJKWHQ STEP 3 Use inside threads of Flared Fitti...

Page 15: ...V12 and FLKV34FIT180 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve FIT180 connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6 CONNECT ELECTRICITY FLKV12 and FLKV34FIT180 Plug ignition into three prong above grade NEMA Rated RXWGRRU VSHFLƓ F GFCI electrical outlet or have electrician hardware ignition into transfor...

Page 16: ...IURP KLVWOH UHH OH LQHV 9 7 DQG 9 7 5HPRYLQJ ŴDUHG ƓWWLQJV ƓUVW PDNHV DWWDFKLQJ WR 7 RU 7 HDVLHU Flared Fitting Whistle Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 250K 299K ưƢƭơ 9 7250 Follow steps 1 8 300K ưƢƭơ 9 7300 Follow steps 1 8 including 3A 3 Connect to Coupling DFLKV34FIT250 Connect x Reducing Fitting to Gas Valve 3A Connect to Coupling DFL...

Page 17: ...VOLT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 290K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee FIT250 or FIT300 Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here FIT250 x Reducing Fitting or FIT300 x 3 Nipple 24 Volt Ignition Drip Leg Plate Coupling 3 4 Tee FIT250 or FIT300 Flared Fitting Whistle Free Flex Line Flared Fitting FIT250 x Reducing Fitting or FIT300...

Page 18: ...50 and DFLKV34FIT300 Connect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall Tighten Whistle Free Flex Line Whistle Free Flex Line Plate GAS LINE IN Key Escutcheon Coupling FIT250 x Reducing Fitting or FIT300 x 3 N...

Page 19: ...ing needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate CROSSFIRE Brass Burner PUSH BUTTON IGNITION SYSTEM CONNECTION DIAGRAMS Up to 300K BTU Systems 1 To place the Spark Igniter in the proper position installer will need to drill a hole in the plate Mea...

Page 20: ...ference and GHVLUHG ŴDPH SDWWHUQ RU electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causing system to fail This is not covered under warranty OPERATING INSTRUCTIONS Keep the area clear and free from combustible materials JDVROLQH DQG RWKHU ŴDPPDEOH YDSRUV DQG OLTXLGV 6ROLG IXHOV...

Page 21: ...rsonal injury or death 3 RQƓUP WKDW RXU 1DWXUDO DV RU LTXLG 3URSDQH VXS ply to the appliance is open or on 4 HIRUH OLJKWLQJ YLVXDOO LQVSHFW ƓUH IHDWXUH DQG UHPRYH any accumulated leaves or other combustible debris 5 If you do not smell gas use the key to turn the key valve or gas control valve to the ON position by turn ing the key to the left 6 7XUQ RQ SRZHU WR WKH ƓUH IHDWXUH ZLWK VZLWFK EXWWRQ ...

Page 22: ...s 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating key valve or gas control without reaching across other jets or the burner Reorient burner if necessary to allow such access 7 Place a long reach lighter through the lighting opening of the gas log slightly a...

Page 23: ...H ZLWKRXW VKDUS bends and installed correctly Check the pressure to be sure it is within recommended ranges RQWDFW D FHUWLƓHG JDV WHFKQLFLDQ IRU VHUYLFH UHSDLU if these suggestions do not solve the issue ELECTRONIC IGNITION SYSTEMS Below are some potential causes and countermeasures to the symptoms below No Pilot Flame Pilot sparks or glow plug glows but pilot won t light o Air in the gas line If ...

Page 24: ...is not responsible for product damaged or lost in transit It is recommended that return items are shipped via a delivery service that can be tracked and or LQVXUHG WR FRQƓUP UHFHLSW Warranty V1 R2_09 12 2019 WARRANTY ALL CROSSFIRE BRASS BURNERS HAVE A LIMITED LIFETIME WARRANTY 50 1 75 1 6p 67 2 6 76 385 CHASED ON OR AFTER JANUARY 1 2019 HAVE A LIMITED TEN 10 YEAR WARRANTY ALL WARMING TRENDS FIREST...

Page 25: ... of Califor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm HDG FDQ EH IRXQG LQ EUDVV ƓWWLQJV 9LHZ WKH IDFW VKHHW DW www p65warnings ca gov Carbon Monoxide Carbon monoxide is a colorless odorless and poisonous gas It is formed during the combustion of various fuels View the fac...

Page 26: ...nd 12 Key DFLKV34FIT250 2x Flex Lines Key Valve and FIT250 For use with any burner over 249K BTU s Kit Includes 2 36 Lx Diameter Flex Lines Key Valve 3 and 12 Key 1 x MM Reducer Fitting and 1 Tee for connection at Plate Coupling 1 x 3 Nipple and 1 Tee for Key Valve connection DFLKV34FIT300 2x Flex Lines Key Valve and FIT300 For use with any 300K BTU Burner Kit Includes 2 36 Lx Diameter Flex Lines ...

Reviews: