24 VOLT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K - 290K BTU SYSTEMS CONTINUED
6. Connect FIT Kit to Key Valve and
Flared Fittings
(DFLKV34FIT250 and DFLKV34FIT300)
Connect ¾ ” x 3” Nipple (FIT250 and
FIT300) to Key Valve.
Then connect the ¾ ” Tee (FIT250 or
FIT300) to the connection just made.
Connect ¾ ” Flared Fittings to the ¾ ” Tee.
Key Valve
FIT250 or
FIT300
(¾ ” Tee)
FIT250 or FIT300
(¾ ” x 3” Nipple)
Apply thread
sealant here
Apply thread
sealant here
Apply thread
sealant here
&RQQHFW)OH[/LQHVWR
Coupling and
Key Valve
Connection
(DFLKV34FIT250 and
DFLKV34FIT300)
Connect ends of 3/4”
Whistle-Free Flex
Lines to Flared Fittings
connected to the 24
Volt Ignition. Then
connect available
ends of the Whistle-
Free Flex Lines to the
Key Valve Connection.
Connect Escutcheon
Plate to Key Valve
through vessel wall.
Tighten.
Whistle-Free Flex Line
Whistle-Free Flex Line
Plate
GAS
LINE
IN
Key
Escutcheon
Coupling
FIT250 (½ ” x ¾ ”
Reducing Fitting)
or FIT300 (¾ ” x 3”
Nipple)
FIT250 or FIT300
(¾ ” x 3” Nipple)
Key Valve
FIT250 or
FIT300
(¾ ” Tee)
Flared
Fitting
Flared
Fitting
Flared
Fitting
Flared
Fitting
24 Volt Ignition
Drip Leg
8. CONNECT
ELECTRICITY
(FLKV12 and
FLKV34FIT180)
Plug ignition into
three prong, above
grade, NEMA Rated,
RXWGRRUVSHFLƓF
GFCI electrical outlet
or have electrician
hardware ignition
into transformer.
WALL
Flared Fitting
Flared Fitting