12
3.2.3 Install support frame and manifold
Fit the clamps supplied with the heat pipe manifold (SHPM~) to each rail of the support frame
(SSF~), placing a pair at the top and at the bottom of each rail as shown.
Install the support frame fixing each rail to the pitched roof brackets by passing the fasteners
supplied through the sides of the rail and the loop on the end of each pitched roof bracket.
Ensure the pair of clamps that are further apart are at the top, as these will secure the
manifold. The clamps closer together go at the bottom and secure the bottom rail.
Fit the bottom rail supplied with the manifold to the lower end of the support frame and
secure in place by tightening the clamps. Ensure the clamps either side of the bottom rail
face inwards towards it and that the edges of the clamps securely grip the lip on the rail.
Fit the manifold to the upper end of the support frame in a similar fashion, again ensuring the
clamps either side of the manifold face inwards towards it and that the edges of the clamps
securely grip the lip on the manifold.
Figure 11: Support frame and manifold installation
WARNING:
Only unpack and install the heat pipe tubes after the rest of the system has been
flushed, filled and pressure tested and the system is ready to be brought into operation i.e.
just
prior to commissioning, in order to prevent damage from excessive heat build-up.