890564_c•en•01.08.2013
We reserve the right to carry out improvements
121
Technical data
14 Technical data
Wisotronic 2/3/4-Channel
Min.
Typ.
Max.
Unit
Supply
Operating voltage
85
230
265
V AC
Frequency
50
60
Hz
Power consumption*
2.4
12
W
Floating output
Switching capacity per channel
at 230 V AC/cos ϕ 0.6
500
VA
Switching capacity per channel
at 24 V DC
72
W
Fuse protection per channel
3.15
AT
Internal temperature sensor
Measuring range
0
50
°C
Miscellaneous
Automatic operation
Type 1
Software class
A
Display
Graphic display, 240 x 320 pixels
Program user guidance
Menu-guided text display
Program entry
4 capacitive buttons/touch wheel
HF receiver
Receiving frequency ASK (OOK)
433.92
MHz
Range (environment without
interference)
30
m
Enclosure
Control panel dimensions
H×W×D
177 × 97 × 42
Degree of protection
IP40
Safety class
II
Location of use
Clean ambient conditions
Test standards
DIN EN 60730-1:2005-12
DIN EN 61000-6-2:2006-03
DIN EN 61000-6-3:2007-09
DIN EN 50366:2006-11
EN 300220-3:2001-03
EN 301489-3:2002-08
Connection
Control panel
Spring terminals
Power unit
Screwed terminals
Miscellaneous
Conformity
Available at http://www.warema.de
Ambient conditions
Operating temperature
0
20
40
°C
Storage temperature
0
20
50
°C
Rel. humidity
(non-condensing)
10
40
85
%RH
* The specified typical power consumption applies when using a multisense
weather station. If additional measurement sensor are connected to the
Wisotronic power unit, the value increases in relation the power consump-
tion of the sensors.