![WAREMA Wisotronic 2 Installation Instructions Manual Download Page 35](http://html.mh-extra.com/html/warema/wisotronic-2/wisotronic-2_installation-instructions-manual_872115035.webp)
890564_c•en•01.08.2013
We reserve the right to carry out improvements
35
NOTE
Conventional low-voltage cables (e.g. JY(St)Y) are normally used for switch,
sensor and network lines. This is usually sufficient regarding EMC interfer-
ence, e.g. in residential rooms at line lengths up to 50 m. By contrast, opti-
mal protection against EMC interference is provided by high-quality lines with
braided shields (no foil shields) and tightly twisted cable pairs. The longer
the line, the greater the susceptibility toward interference. For this reason,
only install high-quality cables.
DANGER
The sun shading/visual privacy products are raised and lowered by a
central UP and central DOWN via the external central switch. Please note
that a switch and not a pushbutton is used here. When a central DOWN is
activated via the external main switch, the safety functions (wind, ice and
precipitation monitoring) remain active.
If the sun shading products are lowered for maintenance, repair or cleaning,
the entire sun shading product must subsequently be taken out of operation
using an in-series disconnecting and isolation switch.
CAUTION
The external 24 V DC voltage made available by the Wisotronic is only
intended for control panels and other WAREMA bus devices (e.g. multisense
weather station). The connection of other components can result in
malfunctions, failures or device damage.
Connection