Wisotronic 2/3/4-channel
Installation instructions
9.1.6 Wind test
In this menu, a wind test can be set to monitor the sensors and an alarm, if
one occurs, can be reset (after resolving a defect or wire break).
NOTE
As a typical value for the duration of the wind test, we recommend 99 hours.
The [
Wind test alarm
] line is for display only. If an alarm is triggered, the
name of the weather station that triggered the alarm appears at the left.
The menu lines below this line list the connectable wind sensors.
Activate all components for which a wind test should be performed.
NOTE
If you accidentally activate the wind test for a sensor that is not connected,
an alarm is always issued after the set duration elapses.
Press the [
Back
] button to return to the [
System
] menu.
Main menu
Settings
Service
Project setup
System
Wind test
System settings