OPERATION
1. At end of workday, close door.
UH30-FND
: Press POWER button.
UL30
: Flip ON/
OFF switch to OFF position.
2. Drain pump will activate and empty machine of water.
3. When draining stops, remove strainer.
4. Remove soil and debris from strainer and set aside.
5.
Unscrew wash and rinse arms manifolds. Remove end-caps and flush arms with
water. Use a brush to clean inside of the arms. If nozzles appear to be clogged, use
a toothpick to remove debris.
SHUTDOWN &
CLEANING
End-cap
Nozzle
180
UH30-FND
UL30
CAUTION!
Do NOT beat
strainers to remove
soil and debris!
!
CAUTION
UL30 has combined wash/
rinse arms.