07610-004-37-37-P
5
Before installing the unit, check packaging and machine for damage. Damaged
packaging might be an indication of damage to the machine. If there is any type
of damage to both packaging and unit, do not throw away the packaging. The
dishmachine has been inspected at the factory before shipping and is expected
to arrive in new, undamaged condition. However, rough handling by carriers or
others might result in damage to the unit while in transit. If this occurs, do not return
the unit to the manufacturer. Instead, contact the carrier and ask them to send a
representative to the site to inspect the damage and request that an inspection
report be completed.
Contact the carrier within 48 hours of receiving the machine as well as the dealer
that sold you the unit.
Remove the box and machine from the pallet before installing. Open the front
door and remove all of the materials from inside. Once unpacked, verify there are
no missing parts (reference the Parts section). If a part is missing, contact the
manufacturer immediately.
All plumbing connections must be made to adhere to local, state, territorial, and
national codes. The installing plumber is responsible for ensuring the incoming
water lines are flushed of debris before connecting to the machine. Note that chips
and materials from cutting processes can become lodged in the solenoid valves
and prevent them from opening or closing. Any valves that are found to be fouled
or defective because of foreign matter left in the water line, and any subsequent
damage, are not the responsibility of the manufacturer.
A water hardness test must be performed. A hardness test kit can be found on the
warning tag that is attached to the incoming plumbing connection on the back of the
machine. If water hardness is higher than 3 GPG, install a water softener or install
the optional Scale Prevention System (SPS). See the Plumbing Options page and
the next section for more information on the SPS.
See the Machine Dimensions page and reference item "B" for water inlet connection
location.
The manufacturer does NOT endorse "Tankless On-demand" water heaters
for use with their dishmachines. The manufacturer DOES endorse, and highly
recommends, the standard "Tank" style water heaters, sized to properly handle the
water heating requirements of the facility.
INSTRUCTIONS
INSTALLATION
INSPECTION
Do not throw away
container if damage is
evident!
UNPACKING
PLUMBING
A water hardness test
must be performed.
The plumber must flush
the incoming water line!
NOTICE