8
07610-004-37-37-P
CAUTION!
Chlorine-based sanitizers can be detrimental to this machine
if the chemical solution is too strong. See a chemical professional to
ensure the dispenser is set-up correctly.
The bottom of the chemical container cannot be located any higher than 8” from the
floor. If the unit is equipped with the 6” or 18” table stand, the highest position will be
14” or 26” from the floor, respectively. It is important to remember that if you decide
to operate the unit in chemical-sanitizing mode, you must ensure an appropriate
chlorine-based sanitizer is used in the final rinse line.
The UH30-FND dishmachine is supplied with detergent and rinse-aid chemical
feeder pumps.
The UL30 dishmachine is supplied with detergent, rinse-aid, and sanitizer chemical
feeder pumps.
Locate the open ends of the chemical tubes with the tube stiffeners and place each
one in the appropriate container.
• Red Tubing = Detergent • Blue Tubing = Rinse-Aid
• White Tubing = Sanitizer
Chemical feeder pumps need priming when the machine is first installed or if the
chemical lines have been removed and air was allowed to enter.
CAUTION!
Water must be in the sump and wash tank before chemicals
are dispensed.
UH30-FND
1. Press and hold prime button toward DETERGENT PRIME until display shows
timer. Priming cycle defaults to 70 seconds. Observe wash tank during priming
cycle. If too much detergent, press prime button to stop priming cycle. If not
enough, run priming cycle again.
2. Press and hold prime button toward RINSE AID PRIME until display shows
timer. Priming cycle defaults to 180 seconds.
CHEMICAL FEEDER
EQUIPMENT
PRIMING CHEMICAL
FEEDER PUMPS
WARNING!
Some of the
chemicals used in
dishwashing might cause
chemical burns if they
come in contact with skin.
Wear protective gear when
handling these chemicals.
If any contact with skin
occurs, immediately
follow the treatment
instructions provided
with the chemicals.
PREPARING
CHEMICAL FEEDER
PUMPS
!
CAUTION
!
WARNING
!
CAUTION
INSTRUCTIONS
INSTALLATION
180