Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-25
9.7.8
Stuffing box (cartridge) KL 30
– KL100
Dismount:
1.
Remove joint (
chapter 9.6)
2.
Dismount snap ring 1017.
3.
Unscrew nuts 1023 of the stuffing box gland.
4.
Pull off stuffing box cartridge.
5.
Clean drive shaft 1000, check on firm seat of snap ring 1554 (the back one)
if necessary exchange it.
Mounting:
1.
Lightly grease drive shaft and set in new cartridge.
The groove in shaft sleeve must engage in dowel pin 1021.
2.
Insert new O-ring 1019 into cartridge.
3.
Reassemble pump by following the instructions for disassembly in reverse order.
4.
Lightly hand tighten gland.
5.
Allow pump to operate for 10 minutes in normal operating conditions in order to settle the
packing. In the event of major leakage, retighten the gland nuts.
Possible damage
The gland must be allowed to leak slightly in order to ensure it is lubricated.
Do not over tighten the packing. If contact pressure is too great, the packing may burn off.
ATTENTION