Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-16
9.6.2
Joint sleeve KL 30
– KL 100
Dismounting:
1.
Remove rotor. (
Chapter 9.4)
2.
Remove existing clamps by opening clamp locks. Then withdraw sleeve(s) 1049.
3.
Check joints. Replace, if necessary. (
Chapter 9.5)
Mounting:
1.
Slide new sleeve over joint and mount clamps. (The clamps will be closed by means of a trade
standard BAND-IT closing tool).
Joints with joint oil (stainless steel cardan joint):
2.
Just mount the middle clamp (or the ones inside),
Erect cardan joint vertically and fill one side of the shaft with oil (
chapter 7)
Push outside clamp over the sleeve and mount it.
Turn the joint and fill other side with oil, push the clamp and fix it.
3.
Mount the pump in reverse order.
Fig. 9-15