Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-8
9.3
Joint bolts with sealed joint connection
9.3.1
KL 20
At this range the connecting bolts are designed as well as rivet pin than dowel pin. At pumps for food
the connecting bolts are sealed with screws and O-rings in this case. (
9.3.2)
9.3.2
KL 30
– KL 100
The joint bolts are sealed with screws and O-rings in this case. For safe hold, the screws are
secured with protective glue. Replace those bolts as follows:
Dismounting:
1.
Undo and remove both screws 1957 of a side of the joint with a screwdriver.
2.
Remove washers 1961 and O-rings 1958. (Washers 1961 do not apply to types KL30S,
KL50S and KL80S)
3.
Push out old bolt 1959.
Mounting:
1.
Insert a new one.
2.
Insert new O-rings 1958 (put on washers), coat the screws with protective glue (e.g. Loctite
270, as used in the factory), screw in and tighten.
3.
Renew by every replacement of rotor or drive shaft the O-ring 1962,
to achieve a constant sealing of the connections.
Figure shows a side of the joint connection
Fig. 9-7