26
W&T
Start-up
3�3 Start-up via the default IP address
In the delivery state and after a reset to the factory set-
tings, the default IP address of the interface
Network 1
is
190.107.233.110.
i
When the interface
Network 1
is connected to the network,
the initial web page for assigning the system password
can be reached via the default IP or the IP address assigned
by WuTility. Make sure that no unauthorized access to the
Microwall occurs until the password is assigned on the initial
web page (e.g. by commissioning with a direct connection to
the respective PC).
i
The commissioning of several Microwalls via their default
IP can only take place one after the other. Only after one
Microwall has received a new IP address may the next Micro-
wall be connected to the network.
On the computer side, the following requirement must be
met:
• The network connection of the computer used must have
an IP address in the range 190.107.233.0/24 and be loca-
ted in the same physical subnet (collision domain) as the
microwall. Changing the IP address of the computer requi-
res administrator rights. Clarify IP changes in advance with
the responsible network administrator.
All other parameters required for initial commissioning are
then assigned via the initial web page using a browser. For
more information, refer to the chapter
Initial Web Page.
Summary of Contents for Microwall Gigabit 55210
Page 6: ...W T...
Page 7: ...7 W T Subject to error and alteration 1 Legal information and safety...
Page 12: ...12 W T...
Page 28: ...28 W T Start up...
Page 48: ...48 W T Operation modes and rule configuration...
Page 64: ...64 W T Security Maintenanceh...
Page 65: ...65 W T Subject to error and alteration 7 Appendix Technical data and form factor Licenses...
Page 75: ...75 W T Index...