36
W&T
Modem Operation
5.1 Serial transmission parameters
Unlike modems for the telephone network, the LAN-Modem is
not able to automatically detect the baud rate of the terminal.
The following transmission format is factory set:
Baud:
9600
Data bits:
8
Parity:
none
Stop bits:
1
Flow control:
RTS/CTS
The AT commands
AT%Bn
,
AT%Dn
,
AT%Pn
and
AT%Sn
can be
used to select the following alternate transmission speeds and
character formats:
Baud:
1200, 2400, 4800, 9600, 19200, 38400, 57600
Data bits:
7, 8
Parity:
none, even, odd
Stop bits:
1, 2
For additional information, refer to the detailed description of
the respective AT command.