If the engine will not start or will not run correctly, confirm the following:
The fuel tank has plenty of gasoline and is free of debris and water.
The oil level is at the Full mark (but do not overfill the oil).
The engine switch is ON (I).
The choke is in the correct (Start or Run) position.
The sparkplug wire is securely connected to the sparkplug.
If there is no voltage at the AC receptacles, disconnect all loads and confirm the following:
The GFCI receptacle has been inspected and reset if necessary.
Reset the thermal circuit breaker if necessary.
The Overload Indicator Light is not ON.
Press the Inverter Reset Switch on the control panel.
If the Output Indicator Light is ON, check the appliance for any defect or fault.
If the Output Indicator Light is OFF and the Overload Indicator Light in ON,
contact Wanco to locate an Authorized Service Dealer.
If there is no voltage at the 12VDC receptacle, shut off the generator and remove the control panel
to inspect the 12VDC fuse. Replace a blown fuse with one of the same size and rating (6.3A slow-
blow 5x20mm). Use of a higher rated fuse may lead to generator damage.