WAMFLO
®
FN200X
3.0
3.0 TECHNICAL INFORMATION
2
FIL.WAMFLO_FN200.EX.M.A7.0522.EN Issue: A7
05.22
31
Modular key Ref.
COILS AVAILABLE
SUITABLE TO WAM
®
PANELS
+
No coil
YES
1
24V 50/60 Hz
YES
3.26 Cleaning system voltage / frequency
Use the field 14 to selected the standard coil WAM® or no coil:
3.27 Options: Board accessories
The WAMFLO
®
FN200 dust collectors can be equipped with devices which measure the pressure difference
between the dirty part and the clean part of the filter, in order to monitor the cleanliness degree of the filter
elements.
The MDPE module (electronic differential pressure meter) is mounted directly on the standard
electronic
control panel
WAM
®
.
The pressure difference is indicated on a 3 digits display. By fixing two operating pressure thresholds (mini
-
mum and maximum), it is possible to run the filter cleaning cycle only when it is actually necessary, thus allow
-
ing a certain degree of energy saving. The preset values are indicated on Preset Value Table (see page 54).
This instrument also allows the remote reading of the ΔP (4-20 mA output) as well as sending of an alarm sig
-
nal (WK output). NOT AVAILABLE FOR ZONE 21.
3.28 Overall dimensions and technical features
For an exact identification of the equipment concerned, see the identification plate.
The transport document shows the serial number and identification codes.
The information regarding the technical features is given in Chapter 10.