5.0 INSTALLATION AND FIXING
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
37
PARAMETER FUNCTION
DIGIT
1
DIGIT
2
DIGIT
3
STATUS
MDPE OPERATING MODE
1
1
MDPE activate and deactivate the control board
and so the cleaning system
2
MDPE just provide the pressure value reading.
ACTIVATION PRESSURE
2
1
Preset value 10 mm H
2
O
2
Preset value 20 mm H
2
O
3
Preset value 30 mm H
2
O
4
9
Preset value 490 mm H
2
O
5
0
Preset value 500 mm H
2
O
DEACTIVATION PRESSURE
3
1
Preset value 10 mm H
2
O
2
Preset value 20 mm H
2
O
3
Preset value 30 mm H
2
O
4
9
Preset value 490 mm H
2
O
5
0
Preset value 500 mm H
2
O
ALARM PRESSURE
4
1
Preset value 10 mm H
2
O
2
Preset value 20 mm H
2
O
3
Preset value 30 mm H
2
O
4
9
Preset value 490 mm H
2
O
5
0
Preset value 500 mm H
2
O
----
5
--
-
Field not used
PROGRAMMABLE OUTPUT
6
1
Output activated by the activation of the cleaning system
(when the cleaning system is ON the output is activated)
2
Output activated by the alarm pressure. (when the pressure
reach the alarm pressure the output is activated)
INTERNAL PARAMETERS
7
4
2
INTERNAL SETTINGS NOT TO BE MODIFIED
INTERNAL PARAMETERS
8
6
4
INTERNAL SETTINGS NOT TO BE MODIFIED
PRESET VALUES TABLE
PARAMETER FUNCTION
PRESET VALUE
MDPE OPERATING MODE
2
ACTIVATION PRESSURE
90 mm H
2
O
DEACTIVATION PRESSURE
40 mm H
2
O
ALARM PRESSURE
400 mm H
2
O
PROGRAMMABLE OUTPUT