5.0 INSTALLATION AND FIXING
SILOTOP R03
2
FIL.100.--.M.EN Issue: A2
06.12
33
Parameter value
Indicator of parameter
to be set
Programming mode
The programming procedure is activated by pressing
P2
and
P3
(ENTER) simultaneously. On pressing the
keys the LH digit on the display will show an identification number (from 1 to 8) relative to the parameter being
examined (see table), while the two remaining ones or just the last one, to the RH, indicates the value selected
for that parameter.
At this point
P1
(UP) or
P2
(DOWN) can be pressed to scroll through the functions that can be set (the LH
digit, indicating the parameter flashes). Once the parameter to be modified has been identified, keep
P2
and
P3
(ENTER) pressed to enter the mode for programming the parameter concerned (the two digits to the RH
(DIGIT2 and DIGIT3) or only the last to the RH -DIGIT3- flash, while the digit to the LH indicating the param
-
eter stops flashing. At this point, use
P1
(UP) and
P2
(DOWN) to scroll through the possible options for that
parameter.
Press keys
P2
and
P3
(ENTER) to store the parameter value modified. When
P1
and
P3
(ESC) are pressed,
the modifications are not saved. Both operations end the parameter programming and return to the menu pre
-
ceding parameter selection. Pressing
P1
and
P3
again will end the program and bring about return to normal
operating mode.
Jamieson Equipment Company | 5314 Palmero Court | Buford, GA 30518 | 800.875.0280 | [email protected]