8
•
The disposal line must be able to be closed odor-tight (e.g. Storz-B coupling).
•
Use tensile strength connections between the individual pipes and fittings
6.4. Ventilation duct
•
The inlet and outlet lines on separator systems for grease must be adequately ventilated
•
For this purpose, the inlet pipe is to be run as a ventilation pipe over the roof. All connection lines longer than 5 m
must be vented separately
•
No other ventilation systems may be connected to these ventilation lines
•
The ventilation line of the supply line and, if necessary, the grease separator can be combined to a collective ventilation
system
6.5. First filling and pressure test
•
Make sure that there are no foreign substances or impurities in the grease separator.
•
Fill the entire grease separator system completely with water.
•
Carry out a pressure test by opening both inspection lids.
•
Close the outlet and inlet with appropriate means.
•
Fill the grease separator system completely with water and ensure that there are no leaks.
•
Restore the functionality of the outlet and inlet.
The operational readiness is established.
7. Operation
If the machine is operated outside of Germany, the safety regulations in the country of use are also
relevant.
Relevant regulations and rules must be observed:
•
Accident prevention regulations
•
Other generally recognized safety, occupational medicine and road traffic regulations
Important
Observe the rules for safe and professional work
In addition to the operating instructions and the accident prevention regulations applicable in the country of use and at
the place of use, the recognized technical rules for safe and professional work must also be observed.
The permissible loads on the grease separator system must not be exceeded!!
7.1. Foreseeable misuse
The grease separator may only be operated by someone who has read and understood the operating manual.
People who are under medication or other drugs are not allowed to operate or maintain the system or carry out other
activities on it.
7.2. Liability
With the machine acceptance, the operator confirms that the supplier has fulfilled all due diligence obligations within the
scope of what is possible and reasonable.
We are liable for defects in the delivery according to the conditions agreed in the order confirmation.
The rectification of defects may only be carried out by qualified personnel.
Our liability is limited to damage caused by normal use.
We are not liable for security deficiencies that are not yet recognizable according to the current state of technology.
7.3. Recommendation
•
Components and accessories are designed exclusively for this product.
•
When purchasing spare or wear parts, only original parts are to be used.
•
We expressly point out that parts and accessories not supplied by us have not been tested and approved by us. The
installation and / or use of such products can negatively affect the system‘s structural properties and thereby impair
active and / or passive operational safety.
The following excludes our liability for consequences:
: