Product Manual WDC200 Electronic Control

 

 

Revision 18 

6. User and Maintenance Instructions 

The electronic control unit has been designed and manufactured from good quality 
materials. If these instructions are followed, the unit will give reliable, efficient 
service. If you need any further information or advice, please contact Wallgate 
customer services. 
 

6.1. 

Operation 

Use the main isolation switch provided by the installer to switch the unit on or off. 
The main isolation switch is located near to the electronic control box. If unit is faulty, 
switch off the control unit until the fault is repaired by a qualified engineer.  

WARNING! Risk of electric shock, serious injury and death. Only trained and 
qualified personnel should remove the cover of the electronic control box. 

The basin, shower and WC are fitted with either Piezo type stainless steel touch 
buttons or infrared sensors.  

Press the button face to operate a Piezo touch button. Once an operation cycle 
starts, it will continue for a fixed period and stop unless the touch button is pressed 
again, which will cancel the operation. The shower and WC cycles, however, cannot 
be interrupted in this way. 

Hold your hand within 50mm of the infrared sensor to operate an infrared sensor. 
The operation cannot be interrupted or stopped when infrared sensors are fitted. 

  The hot and cold basin valves are opened for 10 seconds each.  

  The hot, warm and cold shower valves are opened for 60 seconds each.  

  The WC flush valve is opened to deliver a 6 litre flush. The cistern refill time is 30 

seconds, after which the WC is ready to flush again.  

If the WC is not a cistern type flush, but is flushed directly from the water mains or a 
central tank system, the flush time may have been set with a different cycle time to 
suit the system flow performance.  

  A dual flush option is available, either using one touch button or sensor, or using 

two independent buttons or sensors. One of the two buttons or sensors is used to 
operate a full flush the other for a half flush. Figure 2 on page 11 gives the 
location of the half flush input sockets. Refer to Table 6 on page 23 for 
instructions on setting a dual flush using one Piezo touch button or sensor 
connected to sockets A and E. 

The controller has various function settings that are described in Table 6 on page 23. 

A few important settings and their default states are given in Table 5. 

 

 

Summary of Contents for WDC200

Page 1: ...Product Manual WDC200 Electronic Control For Basins Baths Showers and WCs ...

Page 2: ...2 Product Manual WDC200 Electronic Control Revision 18 AS 1172 Certificate No 23167 RCM Mark Australia ...

Page 3: ...ch the Controller Unit 10 5 4 Connect the Input and Output Cables 11 5 5 Connect the 3 pin output connector 13 5 6 Connect the 3 5mm input connector 13 5 7 Connect the Electrical Supply 13 5 8 Commission the Unit 14 5 9 Purge Cycle function 14 5 10 Lockout function 15 5 11 Piezo touch button and infrared sensor controls 16 5 12 System Test function 17 5 13 Product Time Slots 18 5 14 Hygiene Purge ...

Page 4: ...r improve its product specification at any time without prior notice This manual is specific to the product that it has been supplied with at the date of supply Without prejudice to any warranties in Wallgate Limited s terms and conditions of sale any warranty will be invalidated if the equipment is installed or serviced by unqualified personnel No part of this publication and the information cont...

Page 5: ...these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with amber text on a white background is used to draw your attention to important and useful information NOTE This is a note 2 3 Numbered procedures Steps in procedures are numbered starting from 1 1 This is step 1 2 This is step 2 etc 2 4 Bullet lists 2 4 Bullet lists A bullet list is used to give information t...

Page 6: ...ystem is use for standalone networking of the WDC control units to a dedicated PC or laptop computer You can manage the WDC units through the network You can also adjust time cycle settings lockout settings remote water isolation on individual units or groups RTC settings etc You can also view the unit status in real time and log data Data Logging Activations of the Hygiene Purge function detailed...

Page 7: ...it to a PC or laptop RTC Real Time Clock This is a 24 hour 7 day clock used by the WDC200 for program features such as Time Slots and Hygiene Purge System Test The System Test is a feature that allows you to operate switches and touch buttons and make sure that these operate the necessary outputs such as lights or valve solenoids Time Slots Usage of services such as basins showers and WC pans can ...

Page 8: ...tures User friendly Software menu system with security controlled access Independent control of multiple outlets Fully programmable precise time control of water valve operation that is fully adjustable in situ by the installer customer LOCKOUT function to prevent product misuse that is fully adjustable for the number of user operations operations period lockout period and the LOCKOUT function can...

Page 9: ...as four feet with holes for attaching the unit to the wall using four round head screws No 8 x 30mm 1 25 inch For the location of the mounting feet refer to Figure 1 on page 10 5 2 2 Electrical connections All cables must be connected to the unit using the sockets at the bottom of the unit enclosure The power cable must be connected to the unit through the cable gland The control unit requires an ...

Page 10: ...ke sure the cable sockets at the bottom of the unit point downwards Figure 1 WDC200 Lower Panel Table 2 Legend for Figure 1 Item number Description Function 1 Water Valve Cable Sockets Room 1 Output to washbasin WC and shower valves in Room 1 2 Water Valve Cable Sockets Room 2 Output to washbasin WC and shower valves in Room 2 3 Input Device Sockets Room 1 Input from Piezo touch button or infrared...

Page 11: ...Basin Valve Hot Opens Basin Valve Hot in Room 1 5 Output to WC Flush Valve Opens WC Flush Valve in Room 2 6 Output to Shower Valve Opens Shower Valve in Room 2 7 Output to Basin Valve Cold Opens Basin Valve Cold in Room 2 8 Output to Basin Valve Hot Opens Basin Valve Hot in Room 2 A Input from WC Flush Piezo touch button sensor User input Piezo touch button or IR sensor for WC Flush Room 1 B Input...

Page 12: ...et Ethernet Input OUT Right RJ45 Socket Ethernet Output Optional Inputs I J K L M and N are used when it is necessary to Lockout or disable the basin shower and WC from a remote switch Remotely flush the WC pans Provide the half flush option Clear room lockouts Purge all outlets Connect a hygiene purge water flow sensor There are four types of sockets in the control unit Eight 3 pin female sockets...

Page 13: ...ly contacts the unit Make sure the plug is fully inserted into the socket All inputs are volt free normally open contacts Close input to activate the function a 12v is available to power the infrared sensors on the middle ring contact Input switch cables with fitted 3 5mm stereo jack plugs are available from Wallgate please contact sales if required 5 7 Connect the Electrical Supply To make the el...

Page 14: ...t panel of the WDC200 control unit Refer to figure 3 below for an illustration of the WDC200 front panel Figure 3 Front Panel WDC200 5 9 Purge Cycle function The control unit has a Purge Cycle function you can use when commissioning the installation of the basins showers and WC sanitary ware The Purge Cycle function opens all water valves for the basins showers and WC pans in an automatic sequence...

Page 15: ...th the countdown clock Make sure that water flows freely from each basin shower and WC cistern To stop the cycle switch off the electrical supply to the electronic control unit Correct any problems such as blockages before you run the purge cycle again The control unit has various function settings that can be enabled or disabled The settings are given in section 7 WDC200 Menu Settings 5 10 Lockou...

Page 16: ...nd WCs You can connect either Piezo touch buttons or infrared sensors to the control unit The control unit is set for use with Piezo touch buttons by default If you connect infrared sensors to the control unit you must modify the applicable setting For instructions on how to do this refer to Table 6 on page 23 You do not have to modify this setting if the control unit is factory set for operation ...

Page 17: ...Test function to test the inputs Piezo touch buttons or infrared sensors and the outputs water valves This is useful for fault finding if any of the valves fail to operate You can also use this function to make sure that the Piezo touch buttons and valves have been connected to the correct sockets on the control unit To start the System Test function Press and hold down the and keys for five secon...

Page 18: ...e assigned to a configurable timeslot and when activated the assigned output will only become active if within the allowed time slot This function can be used to manage when sanitary ware is allowed to operate for instance the showers may become inactive during night time periods See pages 28 29 for Time Slot setting information 5 14 Hygiene Purge The control unit can purge an output following pre...

Page 19: ...ion 7 to view the available time settings When an output operates at the set time it is ON for the preset cycle run time as set in Cell Water Settings of the WDC200 menu 5 17 Technical Specifications Table 4 Technical specifications Power supply 115 230V AC Fuse 2 Amp 50Hz Single phase UK Europe Australasia Maximum Rating 60 Watts Refer to model WDCA200 for North America Enclosure IP Rating IP55 W...

Page 20: ...tion The shower and WC cycles however cannot be interrupted in this way Hold your hand within 50mm of the infrared sensor to operate an infrared sensor The operation cannot be interrupted or stopped when infrared sensors are fitted The hot and cold basin valves are opened for 10 seconds each The hot warm and cold shower valves are opened for 60 seconds each The WC flush valve is opened to deliver ...

Page 21: ... Set Date and Time appears on a new unit during first power up or whenever the correct date and time is lost because of a power failure The default date and time is then applied The unit has a minimum backup supply of 48 hours to avoid immediate loss of the date and time settings See Table 6 on page 25 for instructions on setting the date and time Time Slots All Default setting is All which does n...

Page 22: ...water temperature for example on a basin or shower 6 2 Maintenance Wallgate offers a comprehensive service package details of which can be obtained from our customer service department A spare parts service is also available The electronic control unit does not have any user serviceable parts In the event of a fault switch off the electrical supply and contact an authorised electrician to replace ...

Page 23: ...ing Enabled or Disabled Disabled Enable or disable the High Voltage Flush High Volt Flush Enabled or Disabled Disabled Enable or disable Double Press Flush Double Press Flush Enabled or Disabled Disabled Enable or disable the Shower and Basin infrared sensor inputs I R INPUTS Basin IR Input Enabled or Disabled Disabled Shower IR Input Enabled or Disabled Disabled Specify the Time and Date Set Date...

Page 24: ...the default value of 100 Permitted number of WC activations W C Cycle Activations 1 to 100 Activations 4 Activations Time period of a WC activation cycle W C Cycle Period 15 to 1440 Minutes 15 Minutes WC lockout time W C Lockout Time 15 to 1440 Minutes 15 Minutes WC cistern refill time W C Refill Time 1 to 999 Seconds 30 Seconds Copy the water settings from Cell 1 to Cell 2 Copy Settings Cell 1 to...

Page 25: ...to 100 Activations 4 Activations Time period of a shower activation cycle Shower Cycle Period 15 to 1440 Minutes 60 Minutes Shower lockout time Shower Lockout Time 15 to 1440 Minutes 60 Minutes WC outlet run time W C Cycle Time 1 to 999 Seconds 2 0 Seconds WC outlet reduced time W C Reduced Time 1 to 999 Seconds 0 5 Seconds Oli Travel see page 27 Oli Travel 1 to 100 or OFF 100 This must not be set...

Page 26: ...t 1 End 00 00 to 23 00 06 00 Time Slot 2 Start 00 00 to 23 00 06 00 Time Slot 2 End 00 00 to 23 00 12 00 Time Slot 3 Start 00 00 to 23 00 12 00 Time Slot 3 End 00 00 to 23 00 18 00 Time Slot 4 Start 00 00 to 23 00 18 00 Time Slot 4 End 00 00 to 23 00 00 00 Reset Item Time Slots Select Time Slot All None 2 4 1 3 4 3 2 1 All Specify the timings for 4 W C 1 Time Slots Reset the Time Slots Select All ...

Page 27: ...t 1 End 00 00 to 23 00 06 00 Time Slot 2 Start 00 00 to 23 00 06 00 Time Slot 2 End 00 00 to 23 00 12 00 Time Slot 3 Start 00 00 to 23 00 12 00 Time Slot 3 End 00 00 to 23 00 18 00 Time Slot 4 Start 00 00 to 23 00 18 00 Time Slot 4 End 00 00 to 23 00 00 00 Reset Item Time Slots Select Time Slot All None 2 4 1 3 4 3 2 1 All Specify the timings for 4 W C 2 Time Slots Reset the Time Slots Select All ...

Page 28: ...basin Shower Purge Time 1 to 999 Seconds 60 Seconds Specify the period for WC inactivity W C Inactivity Period Off or 1 to 100 Days Off Cell 2 Hygiene Settings Specify the period for Basin Inactivity Basin Inactivity Period Off or 1 to 100 Days Off Specify the period for purging the basin Basin Purge Time 1 to 999 Seconds 180 Seconds Specify the period for shower inactivity Shower Inactivity Perio...

Page 29: ... N N N N N N 09 00 N N N N N N N N 09 30 N N N N N N N N 10 00 N N N N N N N N 10 30 N N N N N N N N 11 00 N N N N N N N N 11 30 N N N N N N N N 12 00 N N N N N N N N 12 30 N N N N N N N N 13 00 N N N N N N N N 13 30 N N N N N N N N 14 00 N N N N N N N N 14 30 N N N N N N N N 15 00 N N N N N N N N 15 30 N N N N N N N N 16 00 N N N N N N N N 16 30 N N N N N N N N 17 00 N N N N N N N N 17 30 N N N N...

Page 30: ...N N 02 00 N N N N N N N N 02 30 N N N N N N N N 03 00 N N N N N N N N 03 30 N N N N N N N N 04 00 N N N N N N N N 04 30 N N N N N N N N 05 00 N N N N N N N N 05 30 N N N N N N N N The default setting for the auto run function is N OFF on all outlets for all time settings Changing the default to Y will set that outlet to switch ON at that time setting 8 Related Documentation Product Manual for WDCM...

Page 31: ... RUN TIME 180 secs BASIN COLD RUN TIME 180 secs 9 2 WDC200 2 The WD200 2 is a standard WDC200 with two setting changes to allow it to operate a CIST21 ELEC The CIST21 ELEC is a low level cistern refer to Wallgate website for details www wallgate com The settings refer to the air pump operation time The setting changes are in CELL 1 WATER SETTINGS and CELL 2 WATER SETTINGS menus and are as follows ...

Page 32: ...bsite for details www wallgate com The settings refer to the water run time on the unit The setting changes are in CELL 1 WATER SETTINGS and CELL 2 WATER SETTINGS menus and are as follows Menu setting WDC200 3 Setting BASIN HOT CYCLE 6 SECONDS BASIN CYCLE ACTIVATIONS 1 BASIN CYCLE PERIOD 15 MINUTES BASIN LOCKOUT TIME 15 MINUTES Menu setting WDC200 3 Setting SHOWER CYCLE 5 SECONDS SHOWER CYCLE ACTI...

Page 33: ...Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...