Product Manual WDC200 Electronic Control
Revision 18
Table 5. Important settings
Setting Name
Default State
Description
Exclusivity
Disabled
This prevents more than one
outlet being operated at a time.
Water Lockouts
Disabled
See Table 6 on page 25 for more
information on this setting.
IR sensor Inputs
Disabled, unless
factory set to
Enabled
See Table 6 on page 25 for more
information on this setting.
Dual Flush
(Double Press)
Disabled
See Table 6 on page 25 for more
information on this setting.
Date & Time (RTC)
The current date and time must
be set for some unit functions to
operate correctly. The unit will
default on power up to a specific
date and time, however, this date
must be modified. The blinking
message Set Date and Time
appears on a new unit during first
power up or whenever the correct
date and time is lost because of a
power failure. The default date
and time is then applied. The unit
has a minimum backup supply of
48 hours to avoid immediate loss
of the date and time settings. See
Table 6 on page 25 for
instructions on setting the date
and time.
Time Slots
All
Default setting is All, which does
not restrict product usage. Refer
to Table 6 on pages 28-29.
Hygiene Purge
Off
Refer to Table 6 on page 327
and 28.
Remote (AUX) Input
set up
I & J - Remote
Lockout
K & L - Remote
Flush
M & N - Half flush
The six Remote inputs can be
assigned to operate any of the
remote functions.
The below scenario details the lockout function using its default settings:
The
Lockout
function is used to prevent misuse of the sanitary facilities. The
function is used to limit the number of operations of any valve within a specified time
period.