10.  GENERAL INSTALLATION ASPECTS AND ELECTRICAL DATA

 

 

General  

1.  It  is  required  that  the  unit  must  be  installed  by  a  registered  plumber  including  all  plumbing  &  drainage  connections  and  all 
electrical aspects including power supply must be connected by a registered electrician. It is the responsibility of the installer to 
obtain all the necessary permits and consents. Ensure full compliance with all applicable local regulations. The owner or owner's 
agent must ensure that the SANISMART PLUS is compatible with the existing or proposed plumbing system design. 
 
2. The installation of the unit and non-return and isolating valve must comply with the following conditions: 
- They are easily accessible for servicing;  
- All fixtures & appliances being serviced are with waste trap installed & are located on the same floor level as the pump. 
- Pump must be installed in a clean, dry, non-floodable position, protected from UV and on a permanently sturdy support.  
- Suitable design & systems are installed to avoid overflow, flooding or unwarranted children interferences or excessive moisture. 
- Suitable care is taken during installation to protect the pump unit and pipes from freezing of liquids within. 
- All the requirements in these instructions are met. 
 
3.  Any 

modifications  not  described  in  this  manual  and  without  written  authorisation  by  a  Wallace  representative  will 

nullify the Wallace Pumps warranty and durability compliance. 

 

Plumbing 

1.  The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code. 
The  connection  of  the  unit's  delivery  pipe  to  a  soil  or  waste  pipe  should  be  kept  at  least  0.5  metre  distance  from  any  o ther 
connection. Also it must not be connected in a section of the pipe which runs the risk of being flooded creating a back pressure 
down the pipework to the unit. The connection point is usually 600 mm above the lowest W.C. connection or the lowest gully trap. 
The connection of the delivery from the unit to a soil or waste pipe should be a swept inspection bend in the direction of flow of 
the soil or waste pipe. 
 
2.  Any horizontal section of the delivery pipework should always have a continuous rise towards the soil or waste pipe connection. 
It should never be level or have a fall. The pipework must be securely strapped and isolated from the building structure to prevent 
vibration and noise transmission. 
 
3.  Install only the supplied full flow non-clog swing check valve within one metre of the pump in a vertical position. This check 
valve to be below and close to the isolating ball valve, supplied with the unit.  
 
5.  All pumped appliances, such as washing machines and dishwashers, must discharge via an approved waste system which 
includes an air gap and a trap.   
 
6.  Ensure that the 40 mm tank vent to outside (if required) is installed in the  top of the unit and that it extends full-bore to the 
external air (the minimum height must be 50mm above the overflow level of the highest fixture discharging into the WALLACE 
SANISMART  PLUS)  or  terminated  elsewhere  as  described  in  the  current  Building  &  Plumbing  regulations

.  DO  NOT  use  air 

admittance valve e.g. a "Hunter Valve" 

venting devices as they do not let air out of the tank.

 

 
7.  It is important from a health and safety reason and for the protection of property, that an overflow relief pipe is plumbed and 
delivered to a safe and visible area in the event that the discharge flows into the SANISMART PLUS exceed the pump hydraulic 
performance capability or caused by a mechanical failure or a pipe blockage. Some of appliances protection and automatic water 
shut off system to be installed as per section 9.0 to further possibly safeguard flooding issue. 
 

10.3 Electrical Connection 

1. The WALLACE SANISMART PLUS is fitted with a high quality 2900 rpm motor: 
Nominal current  : 

2.2 amps 

Motor input  

:  

0.5 kW 

Cable 

 

1.5 metres of 3 core - supplied with the unit 

Cable Plug  

Standard 3 pin domestic earthed - supplied with the unit 

Supply    

1 phase 230 volts 50 Hz. 

 
2.  Overload protection (thermal / overload): - The unit has a built-in automatic motor overload. In the event of an overload trip, 
the pump will not restart automatically as it must be manually reset. Nevertheless always switch off the power in case the fault 
was not an overload trip. Then determine and eliminate the cause of the overload. Press the reset button on top of the main lid to 
ensure pump operates. 
 
3.  Wiring connection: - The electrical wiring connection type should preferably be the "Clipsal Permanent Connection Unit with 
Neon" type, or PDL 253N, or similar. The permanent connection should be fixed in a position where it cannot be reached by a 
person in a bath or shower or standing on a wet surface. 
 
4.  The unit requires a domestic 3 pin earthed single phase power supply.  The appliance must 

not

 be connected to a conventional 

plug, socket or adaptor when installed in a bathroom, unless properly protected by an approved earth leakage circuit breaker  or 
similar. 
 
5.  Refer Section 7 (Warning: for your safety) for additional electrical information. 
 
Always refer to your local power supply authority for details of acceptable wiring, as their requirements over-ride the guidelines 
above. 

Summary of Contents for SANISMART PLUS

Page 1: ...correct operation or servicing Congratulations on your purchase of Sanismart Plus wastewater package pump For this product to meet its expected lifetime please ensure it is installed by a qualified te...

Page 2: ...k right side typically for higher level discharging amenities like hand basin sink etc SANISMART PLUS DIMENSIONS 1 Pump Cover WARNING Pump Cover is not water tight Water dripping on to Pump Cover may...

Page 3: ...ed in the rubber sleeve Use 40 mm pipe to run the vent to a termination point in accordance with the Building and Plumbing Code Do not use an air admittance valve e g a Hunter Valve in the vent pipe 6...

Page 4: ...er property or person due to such jam is not covered under warranty This is a BUDGET model for domestic SECONDARY use only packaged sewage waste water pump This pump is NOT intended for use as the onl...

Page 5: ...Pumps for advice Caution Note Pump as it is not suitable for following Please contact Wallace for suitable solution Condensate water from air conditioning unit Hot and or cold water from relief valve...

Page 6: ...Children persons with reduced physical sensory or mental capabilities or lack of experience knowledge cannot use the product unless they have been given supervision or instruction concerning use of t...

Page 7: ...al failure or Unit jammed due to foreign material or Power failure or Any pipe or valve blockage or In grace of water moisture in the unit or any other reason in addition to ones specified above there...

Page 8: ...ct 230V 1Ph 10A AC Mains Power Supply to Pump from Separate power point If Washing M C OR Dishwasher needs to be stopped on Alarm mode connect 230V AC OUTPUT POWER Phase P Neutral N Earth E from Water...

Page 9: ...valve within one metre of the pump in a vertical position This check valve to be below and close to the isolating ball valve supplied with the unit 5 All pumped appliances such as washing machines an...

Page 10: ...on and disconnection of the power supply to the pump before and whilst carrying out any servicing work on the unit Also ensure no liquid will flow into it during servicing For this product to meet its...

Page 11: ...damage to pump or any property or person due to such malfunction is NOT COVERED UNDER WARRANTY 6 In the event of Liquid inflow in pump higher than unit s capability or Mechanical failure or Unit jamm...

Page 12: ...venting Blockage to pump inlet Inflow rate is too high than pump can pump out Unblock and or change the pipework to the bigger ID size Check with Wallace Visually check that the tank vent pipe is clea...

Page 13: ...nd pump Leakage from the seal gasket between the top lid and the tank Tighten the pipework connections Check and replace if required Check and replace if necessary Check the condition of the seal Repl...

Page 14: ...collection tank 6 Hose Pipe clamp for Pan Connector 7 Rubber Pan Connector 8 Discharge Elbow pipe connected to pump 10 Pressure Switch 11 Capacitor 12 Power Cord with Plug 13 Motor only 14 Mechanical...

Reviews: