background image

G:\INSTRUCT\Sanismart Plus\Sanismart Plus Instructions.docx 9/9/2020 Page 6 

 

 

6.  FEATURES AND BENEFITS 

 

FEATURES 

 

BENEFITS

 

Higher pump head ( longer run & higher vertical height ) 

Pumps higher and further 

Higher flow rate 

Empties faster  and accepts multiple discharges 

Dry mounted motor and pumping unit 

Easier to clean and service and more reliable 

Heavy duty motor 

Longer lasting 

Heat and overload protected motor 

Reduces risk of costly burnt-out motor 

Robust cutter/slicer style impeller 

Cuts through most soft sewage & waste 

One piece collection tank 

No weak joints  

Multiple entry options into the tank 

Can service utilities from different directions 

Pan entry 180mm high with rubber gasket  

Caters for standard P type WC pans 

Option of delivery pipe directions by rotating discharge elbow 

Flexible arrangement to suit site conditions 

 

 

7.  WARNING: FOR YOUR SAFETY

 

 

230V,  50Hz,  1Ph  power  supply  to  Sanismart  Plus  pump  must  be  through  a 

residual  current  device  (RCD

)  as  per  current 

regulations. This power supply must have isolator and suitable overload/surge protection. 
This apparatus must be earthed. To ensure safe operation, check that the three pin power point is earthed & protected by a fuse 
of appropriate rating.  
Also check with your local power supply authority. Their requirements may be additional to and may over-ride those listed above. 
 
Before opening the cover, always switch the power off and ensure no liquid flows into the tank. Always  re-install the cover and 
fasten the safety screw on the cover to comply with electrical regulations. 
To prevent shock or fire hazard, do not expose this unit to rain, any type of moisture, flooding or overflows. 
The wires in the main connection plug are coloured in accordance with the following code: 
Earth: Green/Yellow 

 

Neutral: Blue 

 

Phase: Brown 

 

Children & persons with reduced physical, sensory or mental capabilities, or lack of experience & knowledge, cannot use the 
product unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their 
safety

 

 

8.  LIST OF FITTINGS & ITEMS SUPPLIED & HOW TO USE THEM

 

 

8.1 Unpacking And Inspection. Items supplied with the unit.  
(

All accessories and items are supplied in separate plastic bags and are put in the pump cardboard box. Please check & confirm 

before starting any installation). 

 

Your SANISMART PLUS package should contain the following items 
1 x WALLACE SANISMART PLUS pump unit 
 
2 x Special 40mm DWV pipe fittings (called cap & lining) with rubber gasket. These are used to connect waste 
water discharge pipe to pump inlet connections are the bottom of the pump tank. 
 
1 X Special 40mm DWV pipe fittings (called slab Repair) to connect vent pipe to outside termination point in 
accordance with Building & Plumbing Code and as per local rules and regulations. Do not use an air admittance 
valve

, e.g. a 

"Hunter Valve" in the vent pipe.

  

 

1 x 25 mm PVC swing check valve with solvent weld ends suitable for PVC Pressure Pipe 
 
1 x 25 mm PVC isolating ball valve with solvent weld ends suitable for PVC Pressure Pipe 

 

1 x Toilet Rubber Pan Connector with suitable Hose clips to secure it to collection tank. 

 

1 x Rubber Discharge Elbow with 2 X suitable Hose clips to secure it to collection tank. 

 

1 x Straight Rubber Piece for optional inlet at top of tank with 2 X suitable Hose clips 
 to secure it to collection tank. 

 

2 x Plastic Caps + 2 x Conical g 2 x Plastic nuts to Block 2 inlet ports if not used  
which are at the bottom of collection tanks on two side. 

 

2 x Plastic  2 x suitable screws to secure collection tank to floor 

 

1 x Large 10mm Hex Key (Allen Key) that will require to un-block impeller jam by rotating 
motor from fan end  

 
 

Warning labels to put on appliances to warn against dumping of inappropriate non-organic products in pump 

 

Summary of Contents for SANISMART PLUS

Page 1: ...correct operation or servicing Congratulations on your purchase of Sanismart Plus wastewater package pump For this product to meet its expected lifetime please ensure it is installed by a qualified te...

Page 2: ...k right side typically for higher level discharging amenities like hand basin sink etc SANISMART PLUS DIMENSIONS 1 Pump Cover WARNING Pump Cover is not water tight Water dripping on to Pump Cover may...

Page 3: ...ed in the rubber sleeve Use 40 mm pipe to run the vent to a termination point in accordance with the Building and Plumbing Code Do not use an air admittance valve e g a Hunter Valve in the vent pipe 6...

Page 4: ...er property or person due to such jam is not covered under warranty This is a BUDGET model for domestic SECONDARY use only packaged sewage waste water pump This pump is NOT intended for use as the onl...

Page 5: ...Pumps for advice Caution Note Pump as it is not suitable for following Please contact Wallace for suitable solution Condensate water from air conditioning unit Hot and or cold water from relief valve...

Page 6: ...Children persons with reduced physical sensory or mental capabilities or lack of experience knowledge cannot use the product unless they have been given supervision or instruction concerning use of t...

Page 7: ...al failure or Unit jammed due to foreign material or Power failure or Any pipe or valve blockage or In grace of water moisture in the unit or any other reason in addition to ones specified above there...

Page 8: ...ct 230V 1Ph 10A AC Mains Power Supply to Pump from Separate power point If Washing M C OR Dishwasher needs to be stopped on Alarm mode connect 230V AC OUTPUT POWER Phase P Neutral N Earth E from Water...

Page 9: ...valve within one metre of the pump in a vertical position This check valve to be below and close to the isolating ball valve supplied with the unit 5 All pumped appliances such as washing machines an...

Page 10: ...on and disconnection of the power supply to the pump before and whilst carrying out any servicing work on the unit Also ensure no liquid will flow into it during servicing For this product to meet its...

Page 11: ...damage to pump or any property or person due to such malfunction is NOT COVERED UNDER WARRANTY 6 In the event of Liquid inflow in pump higher than unit s capability or Mechanical failure or Unit jamm...

Page 12: ...venting Blockage to pump inlet Inflow rate is too high than pump can pump out Unblock and or change the pipework to the bigger ID size Check with Wallace Visually check that the tank vent pipe is clea...

Page 13: ...nd pump Leakage from the seal gasket between the top lid and the tank Tighten the pipework connections Check and replace if required Check and replace if necessary Check the condition of the seal Repl...

Page 14: ...collection tank 6 Hose Pipe clamp for Pan Connector 7 Rubber Pan Connector 8 Discharge Elbow pipe connected to pump 10 Pressure Switch 11 Capacitor 12 Power Cord with Plug 13 Motor only 14 Mechanical...

Reviews: