Function of the Dryer
Pro Dry is designed to provide a smooth, controlled and
uninterrupted delivery of dry compressed air. Wet air passes
through a pre-filter and travels down to the bottom valve
assembly. The air is then fed through the bottom of the
desiccant bed and moves through the high performance
desiccant until it becomes dry. On exit from the desiccant
cartridge, the air is passed through the outlet valve assembly.
During this process, the dryer control system cycles the process
air between the two desiccant towers. While one chamber is
on stream removing water vapour, the other is being carefully
depressurised in preparation for regeneration. The desiccant
bed is regenerated by expanding a small amount of dry
process air, or purge air, through the saturated desiccant.
Purge air passes to atmosphere through the silencer, which is
fitted to an exhaust valve. The chamber is then repressurised,
with the control system assuring each chamber is at full
operational pressure prior to changeover.
This ensures a reliable and efficient operation. The air stream is
switched and the cycle repeats on a continuous basis.
General Description
Section 2:
General Description
This manual is valid for the following dryer models
PD004
PD006
PD008
PD010
PD015
PD025
PD035
PD045
PD055
PD065
PD085
PD105
PD135
PD175
PD215
PD275
PD365