48
Pro Dry Instruction Manual
|
Walker Filtration
|
www.walkerfiltration.com
Section 9:
Technical Data
Dryer Sizing Table
Dryer
Model
Unit
Inlet Flow Rate
Dryer
Config.
Dimension (mm)
Weight
Dimension (inches)
Dryer
Pre
FIlter
Nm³/h
SCFM
A
B
C
Kg
lb
A
B
C
PD004
3
/
8
7
4
simplex
490
351
92
13
28.7
19
13.8
3.6
PD004
A038
PD006
3
/
8
10
6
simplex
549
351
92
14
30.9
22
13.8
3.6
PD006
A038
PD008
3
/
8
14
8
simplex
609
351
92
15
33.1
24
13.8
3.6
PD008
A038
PD010
3
/
8
17
10
simplex
679
351
92
17
36.4
27
13.8
3.6
PD010
A038
PD015
3
/
8
25
15
simplex
859
351
92
20
43.0
34
13.8
3.6
PD015
A038
PD025
3
/
8
42
25
simplex
1109
351
92
24
52.9
44
13.8
3.6
PD025
A038
PD035
3
/
8
59
35
simplex
1504
531
92
31
68.4
59
13.8
3.6
PD035
A038
PD045
¾
76
45
simplex
768
530
272
53
116.9
30
20.9
10.7
PD045
A038
PD055
¾
93
55
simplex
868
530
272
59
130.1
34
20.9
10.7
PD055
A078
PD065
¾
110
65
simplex
968
530
272
64
141.1
38
20.9
10.7
PD065
A078
PD085
1
144
85
simplex
1170
530
272
75
165.4
46
20.9
10.7
PD085
A108
PD105
1
178
105
simplex
1480
530
272
91
200.7
58
20.9
10.7
PD105
A108
PD135
1¼
229
135
simplex
1680
530
272
102
224.9
66
20.9
10.7
PD135
A128
PD175
1¼
297
175
simplex
2080
530
272
123
271.2
82
20.9
10.7
PD175
A128
PD215
1½
365
215
duplex
1488
530
459
172
379.3
59
20.9
18.1
PD215
A158
PD275
1½
467
275
duplex
1688
530
459
192
423.4
66
20.9
18.1
PD275
A158
PD365
1½
620
365
duplex
2098
530
483
232
511.6
83
20.9
19.0
PD365
A159
Pressure Correction Factor (PCF)
Operating Pressure
barg
4
5
6
7
8
9
10
11
12
13
14
15
16
psig
58
73
87
102
116
131
145
160
174
189
203
218
232
PCF*
0.62
0.75
0.87
1.00
1.12
1.25
1.37
1.50
1.62
1.75
1.87
2.00
2.12
*Always use the pressure correction factor (PCF) closest to actual inlet pressure condition
Temperature Correction Factor (TCF)
Temperature
°C
20
25
30
35
40
45
50
°F
68
77
86
95
104
113
122
TCF
1.07
1.06
1.04
1.00
0.88
0.67
0.55
Dewpoint Correction Factor (DCF)
Temperature
°C
-40
-70
°F
-40
-94
DCF
1.0
0.7