Product Description: High Pressure Filters

Housing

Category / Assessment Route

Model

SEP

I/Module A

II/Module D1

20HP25
20HP37
20HP50
20HP75

20HP101
20HP150
20HP151
20HP200
20HP201
20HP300
20HP301
20HP302

20 barg (300psig) High Pressure Compressed Air Aluminium Filter Housings

Notified body:

Lloyds Register EMEA, 71 Fenchurch Street, London, EC3M 4BS 

www.walkerfiltration.com

C

0

50

 

HP

 

Stainless

 

Steel

 

High

 

Pressure

 

Compressed

 

Air

 

Filter

 

Housings

Housing

Category / Assessment Route

Model

SEP

I/Module A

II/Module D1

350HP24
350HP26
350HP50
350HP75
350HP100

350 HP Stainless Steel High Pressure Compressed Air Filter Housings

Housing

Category / Assessment Route

Model

SEP

I/Module A

II/Module D1

50HP25
50HP37
50HP50
50HP75
50HP101
50HP150
50HP151
50HP200
50HP201

50 barg (725psig) High Pressure Compressed Air Aluminium Filter Housings

Housing

Category / Assessment Route

Model

SEP

I/Module A

II/Module D1

C

0

25

C

0

37

C

0

50

C75
C101
C150
C200
C201

Housing

Category / Assessment Route

Model

SEP

I/Module A

II/Module D1

100HP24
100HP49
100HP75
100HP100
100HP101
100HP150
100HP200

100 HP Stainless Steel High Pressure Compressed Air Filter Housings

04 396 001 01 rev B:04 396 001 01.qxd 12/05/2010 09:58 Page 2

COV0310124/1

COV0310124/1

COV0310124/1

COV0310124/1

COV0310124/1

EC Declaration of Conformity (

2014/68/EU

)

This declaration of conformity is issued under the sole responsibility of the 

manufacturer. I declare on behalf of Walker Filtration Ltd (the manufacturer) and 

as authorised representative, that the stated products fulfil the requirements of the 

new approach directives.

Na

me: Simon Wise

Position: 

Chief Technical Officer (CTO)

Signed:  

Date: 

July 2016

Manufactured in the UK by Walker Filtration
www.walkerfiltration.com

Notified body (Not applicable to SEP or Cat I Products)
Lloyd’s Register V

 

erification Ltd– Notified Body No 0038

71 Fenchurch Street, London EC3M 4BS. England

Quality Assurance System: ISO9001:2008 – LRQ0930553

Lloyds Register Quality Assurance Ltd (LRQA)
1 Trinity Park, Bickenhill Lane, Birmingham, B37 7ES, United Kingdom

Assessment based on Group 2 Gas service

Standards Used: ASME VIII Division 1 - Rules for Construction of Pressure Vessels

20HP100

350HP101

Summary of Contents for 20HP25

Page 1: ...Barg 300 psig 50 Barg 725 psig INSTALLATION MAINTENANCE INSTRUCTIONS Gebrauchs und Wartungshandbuch Manuel d utilisation et d entretien Manuale di istruzioni e manutenzione Manual de instrucciones y...

Page 2: ...nt Route Model SEP I Module A II Module D1 100HP24 100HP49 100HP75 100HP100 100HP101 100HP150 100HP200 100 HP Stainless Steel High Pressure Compressed Air Filter Housings 04 396 001 01 rev B 04 396 00...

Page 3: ...ould be carried out using a nipple or coupling with the correct thread form for the housing and should be suitably rated for the operating temperature and operating pressure Maintenance 1 General main...

Page 4: ...f r die Betriebstemperatur und den Betriebsdruck geeigneten Daten aufweisen Wartung 1 Die Einhaltung der allgemeinen Wartungsarbeiten und die regelm ige Kontrolle sorgen f r eine korrekte Funktion und...

Page 5: ...is en utilisant un mamelon ou un raccord muni du filet appropri pour le bo tier et con u pour la temp rature et la pression de service Entretien 1 Il faut effectuer des op rations d entretien g n rale...

Page 6: ...un nipplo o un raccordo con la forma di filettatura adatta al contenitore e deve essere regolato per la temperatura e la pressione operative Manutenzione Dovrebbero essere effettuati interventi di man...

Page 7: ...ratura nominales de servicio adecuadas Mantenimiento 1 Para que el funcionamiento sea correcto y conservar la fiabilidad del sistema a largo plazo deber n hacerse mantenimientos generales y comprobaci...

Page 8: ...ltes sammen En serietilslutning af en eller flere af ovenn vnte huse skal udf res med en nippel eller kobling med den korrekte gevindform for huset og skal have den passende klassificering for driftst...

Page 9: ...de maximale werktemperatuur en werkdruk Onderhoud 1 Algemeen onderhoud en regelmatige controles dienen te worden uitgevoerd om een juiste werking te garanderen en een betrouwbaar systeem te handhaven...

Page 10: ...1 10 HP420 Grade 100HP100 Grade 1 680 400 132 26 265 150 10 5 23 2 5 1 4 1 11 6 HP710 Grade 100HP101 Grade 1 1200 700 132 26 480 300 14 7 32 4 5 1 4 1 19 12 HP730 Grade 100HP150 Grade 1 1 2 1700 1000...

Page 11: ...ade 50HP37 Grade 3 8 250 147 63 15 190 50 0 27 0 6 2 1 2 1 2 7 1 2 2 HP1550 Grade 50HP50 Grade 1 2 450 265 114 38 305 150 2 6 5 7 4 1 2 1 1 2 12 6 HP2040 Grade 50HP75 Grade 3 4 550 324 114 38 305 150...

Page 12: ...retien des boitiers et des l ments de filtre Si sottolinea che la principali precauzioni nazionali concernenti la salute e la sicurezza devono essere osservate durante il servizio sia dei contenitori...