Thank you very much for your confidence. We wish you much pleasure and success with your new 
device.   

The LED 500 Fluorescent Light is equipped with long-living, energy-saving LED. The Light is especially 
developed for ambitious beginners and professional users in film and studio photography. It is 
characterized through its longevity, stable colour temperature and constant luminance (without 
flickering).   

The barndoors provide a rectangular illumination, cover large projecting area and distribution without 
shadow effect. An electronic ballast guarantees high power efficiency. The body of the Fluorescent 
Light is attractive in its appearance and made up of aluminium alloy. The Fluorescent Light is the right 
choice for you, also because of its security and compatibilty!   

 

The main features of your device as follows: 

 

stable light with constant colour temperature 

 

sturdy aluminium/metal housing 

 

rotatable and tiltable socket, which fits on every common lamp tripod 

 

low heat development 

 

low energy demand 

 

long service life 

 

vertical and horizontal usage possible 
 

 

 

Please read these instructions carefully before using your device for the first time. It includes 
everything you need to know to avoid physical injuries and damages.   

 

Please pay attention to all safety notes in this instruction manual.   

 

Please keep this manual safe. In case of selling or leaving the device to other persons, please 
don´t forget to hand this manual over as well.   

 
 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LED 500

Page 1: ...1 Copy of Instruction Manual LED 500 Fluorescent Light Gewerbering 26 86666 Burgheim Tel 49 84 32 9489 0 Fax 49 84 32 9489 8333 eMail info foto walser de www foto walser de ...

Page 2: ... 6 1 Mount on tripod optional 7 6 2 Connect to power supply 8 7 Operation of the device 8 7 1 Adjust tilt angle 8 7 2 Switch device on and off 8 7 3 Switch lamps on and off 8 8 Transportation and storage 8 9 Solve problems 9 10 Maintenance 9 10 1 Continuous inspections 9 10 2 Cleaning 9 10 3 Change lamps 10 10 4 Change micro fuse 10 11 Accessories and options 10 12 Spare parts 10 13 Disposal and e...

Page 3: ...tractive in its appearance and made up of aluminium alloy The Fluorescent Light is the right choice for you also because of its security and compatibilty The main features of your device as follows stable light with constant colour temperature sturdy aluminium metal housing rotatable and tiltable socket which fits on every common lamp tripod low heat development low energy demand long service life...

Page 4: ...k into the lamp directly This could lead to injuries Please avoid persons and animals looking into the flash directly WARNING Danger of crashing entrapment and fire through the falling down of the device The weight of the device is approx 3kg Make sure that the device is always positioned tilt and skid resistant and stored securely Keep out of reach of children and animal They could overturn the d...

Page 5: ...n the device Never repair the device on your own The device should only be repaired by electricians Please follow this instruction manual for maintaining your device Please just use spare parts which are conform to the required specifications See Technical Specifications WARNING The device can overheat if you operate it with covered ventilation slots The device itself accessories and easily inflam...

Page 6: ...first time use Remove the protection foil from the barndoors Please check if the delivery is complete o 1 Fluorescent Light 500W o 1 Power Cord o 1 Instruction Manual in German and English Please check if the delivery is undamaged ADVICE If the delivery should be incomplete or damaged please contact info foto walser de or our service hotline with the telephone number 49 84 32 9489 0 ADVICE We rese...

Page 7: ...he following operation steps when using the device for the first time to avoid damages on the device WARNING Please note the safety notes in the respective chapters throughout operation Mount the device on a tripod optional Adjust tilt angle Connect to power supply Switch on device Switch lamps on off 6 Preparation for operation 6 1 Mount the device on a tripod optional You can mount the Fluoresce...

Page 8: ...vice and with the power socket 7 Operation of the device 7 1 Adjust tilt angle Open tilt lever Adjust the required tilt angle Tighten tilt lever 7 2 Switch the device on and off Switch the device on Set On Off tappet switch on I The device is ready for operation If the lamps are switched on The lamps light up Switch off device Set On Off tappet switch on O If the lamps were switched on The lamps g...

Page 9: ... through an electrician 10 Maintenance 10 1 Continuous inspections What you should do Before every operation With every change Check all cables and plugs for damages In case of damage WARNING Danger of electric shock and fire through short circuit The device should be repaired by an electrician immediately X Check if the socket of the lamps is firmly In case of damage WARNING Danger of electric sh...

Page 10: ...h short circuit A micro fuse which is not conform with the required specifications doesn t protect against the overloading of the device Please just use a micro fuse which is conform with the required specifications See Technical specifications Switch off device Switch device on and off Disconnect from power supply Unplug power cord Open fuse holder Use a small screwdriver to lift up the fuse hold...

Page 11: ... fuse 5A Power supply AC 220 230 V 50 Hz Weight approx 3 0 kg Vertical pivoting radius 180 Dimensions HxWxD approx 19 cm x 35 cm x 10cm Accessories Power cord 4 m instruction manual Output at 2m distance approx 630 Lux Lamps Colour temperature 6200 K Permitted operation temperature 10 C to 40 C Storage conditions Dry and dust free in carton at 20 C to 50 C ...