7
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
1.
Remove either the left or right hand side panel to allow access to the electrical connection terminal
block. Fit the cable through the small grommet located at the rear of the unit and connect to the
terminals as marked.
2.
If required, the appliance can be connected to two 13 or 15 amp single phase supplies by removing
the insulated wire loom between the left and right hand terminal blocks. Independent supplies can
then be connected to each side.
3.
The operating voltage of the salamander is stated on the rating plate affixed to the right hand side
panel front bottom corner. This information is also shown in the “Specifications” Section of this
manual. Ensure that the available voltage is correct.
NOTE:
This appliance must be grounded / earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.
Commissioning
1.
Before leaving the new installation, check that all the connections are correct and, and that the unit
functions in accordance with the operating instructions.
2.
Check the current draw and loading for the equipment. Refer specification section for correct
electrical requirements.
NOTE:
If for some reason it is not possible to get the unit to operate correctly, turn off the
electrical power supply and contact a qualified service person. The supplier of this
unit will be able to recommend a suitable person.
Make sure that the electrical supply is turned off before any service or maintenance
work is carried out.
Installation
Rating Plate
Fig 5