6
Clearances
This unit must be installed on a non-combustible wall or tailored stand with the following clearances:-
NOTE: Top clearances can be reduced where local fire protection system is provided, if
allowed by the local regulations.
Wall Mounting (to non-combustible wall only)
NOTE: Only non-combustible materials can be
used in close proximity to this
appliance.
1.
Fix the wall mounting bracket to the wall
with six screws, in such a position that the
top of the bracket is level and at least
945mm (38”) above any surface beneath the
unit. This will ensure that the bottom of the
Salamander is at least 600mm (24”) above
any surface.
2.
Fit the two black plastic spacers to the top
rear corners of the unit.
Leave them
unscrewed by approximately 5mm.
3.
Fit the two adjusting screws / bolts into the
nutserts at the bottom rear corners of the
unit. These should protrude approximately
30mm from the rear of the Salamander.
4.
Lift the Salamander onto the wall bracket, lining up the black plastic
spacers on the salamander with the mounting notches in the bracket.
5.
Lower the Salamander onto the mounting bracket.
6.
Tighten the black spacers securely and adjust the levelling screws /
bolts to ensure that the unit is level.
~ 5mm
~30mm
Installation
Combustible Surface
Non-Combustible Surface
Left/Right hand side
50mm
0mm
Rear
50mm
0mm
Top Clearance to;
Extraction Hood
200mm
Ceiling (subject to all local regulation requirements)
300mm
Grease Arresting Filter
400mm
Fig 1
Fig 2
Fig 3
Fig 4