27
- All Other Markets
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Open Burner
Main Burner
Ø 2.45mm
Ø 4.50mm
Pilot Burner ('PF' Models only)
0.30
0.60
Griddle
Main Burner
Ø 2.10mm
Ø 3.40mm
Pilot Burner
0.35
0.60
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-4 kPa
0.75 - 1.5 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified)
Open Burner
Main Burner
Ø 1.50mm
Ø 1.40mm
Pilot Burner ('PF' Models only)
0.20
0.20
Griddle
Main Burner
Ø 1.30mm
Ø 1.20mm
Pilot Burner
0.23
0.23
Burner Aeration Setting
Fully open
Supply Pressure
2.75 - 4.5 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw