background image

11 

NOTE:   

 

It  is  most  important  that  this  Cooktop  is  installed  correctly  and  that  operation  is  correct 

before use.  Installation shall comply with local gas, health and safety requirements. 

 

This  appliance  shall  be  installed  with  sufficient  ventilation  to  prevent  the  occurrence  of 

unacceptable  concentrations  of  health  harmful  substances  in  the  room,  the  appliance  is 

installed in. 

 

Waldorf Cooktops are designed to provide years of satisfactory service, and correct installation is essential 

to achieve the best performance, efficiency and trouble-free operation. 

 

This appliance must be installed in accordance with National installation codes and in addition, in  

accordance with relevant National / Local codes covering gas and fire safety. 

 

Australia / New Zealand: 

- AS/NZS5601  

- Gas Installations. 

United Kingdom:  

 

- Gas Safety (Installation & Use) Regulations 1998. 

  

 

 

 

 

- BS6173 

- Installation of Catering Appliances. 

  

 

 

 

 

- BS5440 1 & 2 

- Installation Flueing & Ventilation. 

Ireland: 

 

 

 

- IS 820 

- Non - Domestic Gas Installations. 

 

Installations must be carried out by qualified service persons only.  Failure to install 
equipment to relevant codes and manufacturer

s specifications shown in this section will void 

the warranty. 

 

Components having adjustments protected (e.g. paint sealed) by the manufacturer are only  
to be adjusted by an authorised service agent. They are not to be adjusted by the installation 
person. 

 

 

 

Remove  all  packaging  and  transit  protection  from  appliance  including  all  protective  plastic  coating 
from exterior stainless steel panels. 

 

Check  equipment  and  parts  for  damage.    Report  any  damage  immediately  to  the  carrier  and 
distributor. 

 

Report any deficiencies to distributor who supplied appliance. 

 

Check available gas supply is correct to that shown on  Rating Plate attached to  underside of R/ H 
side,  front  Cooktop  lower  trim,  for  Bench,  Cabinet  Base  and  Leg  Stand  Models.    For  Refrigerated 
Base Models, rating plate is located inside right hand front panel and can be viewed through upper 
grille. 

 

1. 

Installation must allow for a sufficient flow of fresh air for the combustion air supply. 

2. 

Installation must include adequate ventilation means, to prevent dangerous build up of combustion 

products. 

3. 

Never directly connect a ventilation system to appliance flue outlet. 

4. 

Position appliance in its approximate working position. 

5. 

All air for burner combustion is supplied from underneath appliance.  Legs must always be fitted and 

no obstructions placed on underside or around base of appliance, as obstructions will cause incorrect 

operation and / or failure of appliance. 

 

NOTE:  Do  not  obstruct  or  block  appliance  flue.    Never  directly  connect  a  ventilation  system  to 

appliance flue outlet. 

Combustion Air Requirements: 

 

RN8200G 

RN8400G

 

RN8600G 

RN8800G 

Natural Gas (G20) 

12m

3

/hr 

24m

3

/hr 

36m

3

/hr 

48m

3

/hr 

LPG / Propane (G31) 

13m

3

/hr 

25m

3

/hr 

38m

3

/hr 

50m

3

/hr 

Summary of Contents for RNL8200G Series

Page 1: ...d O p e r a t i o n M a n u a l Gas Cooktops Series RN8200G RNL8200G RNB8200G RNLB8200G RN8400G RNL8400G RNB8400G RNLB8400G RN8600G RNL8600G RNB8600G RNLB8600G RN8800G RNL8800G RNB8800G RNLB8800G 228...

Page 2: ...es tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455...

Page 3: ...uirements Unpacking Location Clearances Assembly Fitting Adjustable Feet Rear Rollers to Leg Stand Units Fitting Adjustable Feet Rear Rollers to Cabinet and Refrigeration Bases Gas Connection Commissi...

Page 4: ...r adapting the appliance to the conditions for use in that country GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT...

Page 5: ...old Front 2 Open Burner Options F With Flame Failure Protection PF With Pilot and Flame Failure Protection 3 Base Stand Options B Bench Mount CB Cabinet Base excluding RN8200G Series LS Leg Stand excl...

Page 6: ...nection information overleaf Input Rate N H G C each Open Burner 28 MJ hr 28 MJ hr each 300mm Griddle Section 21 MJ hr 21 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0...

Page 7: ...loor 55mm for bench top B models and is reached from beneath appliance Refer to Dimensions section With exception of RN8200G B and RN8203G B models which are 100mm from right hand side 32mm from rear...

Page 8: ...6 Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...

Page 9: ...7 RN8200G Models not available in Cabinet Base option R Rating Plate Location for this option R Refer to Page 9 for Cooktop options...

Page 10: ...8 RN8200G Models not available in Leg Stand Base option Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...

Page 11: ...9 RN8200G and RN8400G Models not available in Refrigerated Base option Refer to Page 9 for Cooktop options Rating Plate Location for this option R R...

Page 12: ...Cabinet Base CB or Leg Stand LS model options RN8600G and RN8800G are available in Bench Model B Cabinet Base CB Leg Stand LS or Refrigeration Base RB model options For Refrigeration Cabinet Specific...

Page 13: ...agent They are not to be adjusted by the installation person Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels C...

Page 14: ...d with each kit Bench Models 1 Check that all feet are fitted 2 Adjust the four feet to make Cooktop steady and level 1 Remove all pot stands pot stands supports burner caps burner bowls griddle plate...

Page 15: ...ray to rear cooktop legs and tighten up bolts using a 24mm socket b Fit rear rollers to rear leg supports c Secure rear rollers to rear leg supports using locating screw supplied d Tighten screw using...

Page 16: ...liance Rear Rollers fitting 1 Raise appliance from floor by approximately 75mm using suitable lifting equipment i e Palletiser Forklift to allow rear adjustable feet to be removed 2 Unscrew and remove...

Page 17: ...ppliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to correct gas type that appliance will operate on Regulator outlet press...

Page 18: ...of Date of Purchase Date of Installation and Serial Number of Appliance recorded and kept with this manual These details can be found on the Rating Plate For Bench Cabinet Base and Leg Stand Models Ra...

Page 19: ...Option Lighting the Griddle NOTE Only Cooktops fitted with Griddle Option and Pilot Flame Failure Option will have a Pilot position on Gas Control Knob Griddle Options will also have a piezo igniter f...

Page 20: ...ned ON as burner will automatically light itself off the pilot burner Flame Failure Protection is incorporated for each burner by way of a thermo electric system which will shut off gas supply to that...

Page 21: ...lockwise to Low Flame position g When main burner is not required depress and turn gas control knob clockwise back to OFF position Turning OFF the Griddle Burner Pilot a To turn OFF griddle but keep p...

Page 22: ...r cleaning material has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Burner Body Griddle Plate Grease Tr...

Page 23: ...plate surface thoroughly with a scraper tool and brush off any deposits with a soft bristled brush 2 Stubborn or accumulated carbon deposits can be removed with a griddle stone or a scotch bright pad...

Page 24: ...essure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at le...

Page 25: ...e the pot stands burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refi...

Page 26: ...ize injectors as shown in Gas Specifications Tables at rear of this section 4 Refit the following Re connect pilot supply tube to pilot burner Re connect piezo igniter to mounting bracket Refit main b...

Page 27: ...Re adjust regulator if required 5 Screw cap nut back onto regulator 1 On completion of gas conversion replace gas type identification label located at 2 Rear of appliance above gas connection 3 Besid...

Page 28: ...r Aeration Setting Fully open Fully open Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 5 mbar 26 mbar Gas Regulator Cap Screw Open Burner Main Burner 2 45mm 1 50mm Pilot Burner PF Models...

Page 29: ...50mm Pilot Burner PF Models only 0 30 0 60 Griddle Main Burner 2 10mm 3 40mm Pilot Burner 0 35 0 60 Burner Aeration Setting Fully open Fully open Supply Pressure 1 13 3 4 kPa 0 75 1 5 kPa Burner Oper...

Page 30: ...r Town Gas 0 60 PF Option only 229442 Pilot Bracket Assembly PF Option only 229444 Pilot Burner Shield PF Option only 227405 Gas Control F Models 227403 Gas Control PF Models 227967 Knob Open Burner F...

Page 31: ...t 228799 900mm Plinth Kit 228803 1200mm Plinth Kit 228801 Refrigeration Base 900mm Plinth Kit 228805 Refrigeration Base 1200mm Plinth Kit For Refrigeration Cabinet Replacement Parts information refer...

Page 32: ......

Reviews: