Waldorf RNB8910GC Installation And Operation Manual Download Page 4

Introduction

 

We are confident that you will be delighted with your WALDORF Gas Range Convection Oven, and it will 

become a most valued appliance in your commercial kitchen. 

To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things 

you can do. 

 

Firstly: 

Please read the instruction book carefully and follow the directions given.  The time taken will be well 

spent. 

 

Secondly: 

If you are unsure of any aspect of the installation, instructions or performance of your appliance,  

contact your WALDORF dealer promptly.  In many cases a phone call could answer your question. 

 

CE Only: 

These instructions are only valid if the country code appears on the appliance.  If the code does not  

appear on the appliance, refer to the supplier of this appliance to obtain technical instructions for  

adapting appliance to conditions for use in that country. 

 
 
 

G

REAT

 

CARE

 

MUST

 

BE

 

TAKEN

 

BY

 

THE

 

OPERATOR

 

TO

 

USE

 

THE

 

EQUIPMENT

 

SAFELY

 

TO

 

GUARD

 

IT

 

AGAINST

 

RISK

 

OF

 

FIRE



T

HE

 

APPLIANCE

 

MUST

 NOT 

BE

 

LEFT

 

ON

 

UNATTENDED



I

T

 

IS

 

RECOMMENDED

 

THAT

 

A

 

REGULAR

 

INSPECTION

 

IS

 

MADE

 

BY

 

A

 

COMPETENT

 

SERVICE

 

PERSON

 

TO

 

ENSURE

 

CORRECT

 

AND

 

SAFE

 

OPERATION

 

OF

 

YOUR

 

APPLIANCE

 

IS

 

MAINTAINED



DO NOT 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPOURS

 

OR

 

LIQUIDS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

 

APPLIANCE



DO

 

NOT

 

SPRAY

 

AEROSOLS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

APPLIANCE

 

WHILE

 

IT

 

IS

 

IN

 

OPERATION

Warning 

 
 
 



This appliance is for professional use and is only to be used by qualified 
persons. 



Only authorised service persons are to carry out installation, servicing or gas 
conversion operations. 



Components having adjustments protected (e.g. paint sealed) by the 

 

manufacturer should not be adjusted by the user / operator. 



DO NOT operate the appliance without the legs supplied fitted. 

Caution 

 
 

I

MPROPER

 

INSTALLATION

ADJUSTMENT

ALTERATION

SERVICE

 

OR

 

MAINTENANCE

 

CAN

 

CAUSE

 

PROPERTY

  

DAMAGE

INJURY

 

OR

 

DEATH

.  R

EAD

 

THE

 

INSTALLATION

OPERATING

 

AND

 

MAINTENANCE

 

INSTRUCTIONS

  

THOROUGHLY

 

BEFORE

 

INSTALLING

 

OR

 

SERVICING

 

THIS

 

APPLIANCE

Warning 

 
 
 
INSTRUCTIONS

 

TO

 

BE

 

FOLLOWED

 

IN

 

THE

 

EVENT

 

THE

 

USER

 

SMELLS

 

GAS

 

ARE

 

TO

 

BE

 

POSTED

 

IN

 

A

 

PROMINENT

 

LOCATION

.  

THIS

 

INFORMATION

 

SHALL

 

BE

 

OBTAINED

 

BY

 

CONSULTING

 

THE

 

LOCAL

 

GAS

 

SUPPLIER

Warning 

Summary of Contents for RNB8910GC

Page 1: ...s t a l l a t i o n a n d O p e r a t i o n M a n u a l RN8910GC RNL8910GC RNB8910GC RNLB8910GC Gas Range Convection Oven Date Purchased Serial Number Dealer Service Provider 232780 12 For use in GB...

Page 2: ...s tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455...

Page 3: ...n Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 10 Operation Guide Description of Controls Open Burners Oven Pilot Ignition Oven Main Burner Thermostat Oven Fan Turn...

Page 4: ...NCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE O...

Page 5: ...e Protection General A heavy duty general purpose gas convection oven range created for compact modular kitchens It is available on industrial adjustable feet or on robust rollers Open Burners are ava...

Page 6: ...inal 6 5 kW 7 8 kW 6 5 kW 7 8 kW Reduced 1 75 kW 1 75 kW Gas Rate nett Nominal 0 69 m3 hr 0 83 m3 hr 0 51 kg hr 0 61 kg hr Reduced 0 19 m3 hr 0 14 kg hr Supply Pressure 20 mbar 37 mbar Burner Operatin...

Page 7: ...roximately 130mm from right hand side 32mm from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions section Connection is BSP male thread Electrical Supply Requirements...

Page 8: ...6 Dimensions RN L 8910GC Cooktop Options...

Page 9: ...es and manufacturer s specifications shown in this section will void the warranty Components having adjustments protected e g paint sealed by the manufacturer are only to be adjusted by an authorised...

Page 10: ...wing checks should be made before installation a Gas Type the appliance has been supplied for is shown on coloured stickers located above gas connection and on rating plate Check this is correct for g...

Page 11: ...ed and readily accessible in case of fire 1 Check electricity supply is correct as shown on Rating Plate attached to front right hand corner of bottom sill 2 Appliance is fitted with a 10 Amp 3 pin pl...

Page 12: ...t Oven Fan Turning Oven to Stand By Mode Oven Shut Down 1 Description of Controls Heating Indicator Lamp Amber Power Indicator Lamp green Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burn...

Page 13: ...Main burner will extinguish and pilot will remain alight b To turn OFF the PILOT depress and turn gas control knob clockwise back to OFF position PILOT burner will extinguish Open Burners F Flame Fai...

Page 14: ...osition This puts gas valve in Stand By position and control of main burner is now carried out through oven thermostat control 4 Turn oven thermostat to desired oven temperature setting required this...

Page 15: ...cently been turned OFF and you want to re light oven the interlock will not allow gas valve to be turned to main burner position until interlock has reset Approximately 1 minute DO NOT FORCE GAS VALVE...

Page 16: ...rial has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical supply before c...

Page 17: ...pty spill tray and wash with warm soapy water 5 Dry all components thoroughly and re assemble Oven Interior Cleaning 1 Do not use wire brushes steel wool or other abrasive materials to clean oven inte...

Page 18: ...Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple fault...

Page 19: ...E CORDSET P N 7 BLUE 8 10 HEAT ORANGE CLEAR MICROSWITCH 003004 COM N O 13 12 E BLOCK TERMINAL E 12 GREEN 11 CAPACITOR BLACK BROWN BLUE BLACK BROWN GREEN MOTOR WHEN VIEWED FROM INSIDE OVEN FAN DIRECTIO...

Page 20: ...nds burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot sta...

Page 21: ...bracket Refit main burner and secure clamp bracket Refit sole plate s and lower lintel NOTE There is no Low Fire adjustment on the gas control valve for the GC Oven Refit oven control panel Gas Regula...

Page 22: ...ate Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in...

Page 23: ...ation Setting Fully Open Fully Open Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas G20 Propane G31 Open Burner Main Burner I...

Page 24: ...s Open Burner Main Burner 2 45mm 4 50mm Pilot Burner PF Option Only 0 30 0 60 Oven Main Burner 2 6mm 5 0mm Pilot Burner 0 35 0 60 Low Fire 1 5mm 2 50mm Burner Aeration Setting Fully Open Fully Open Su...

Page 25: ...30 026136 Pilot Injector LP Gas Butane 0 20 232309 Pilot Injector Town Gas 0 60 229442 Pilot Bracket Assembly 229444 Pilot Burner Shield 227403 Gas Control with Pilot and Flame Failure 227384 Knob Op...

Page 26: ...011987 Thermostat 50 320 C 230312 Gas Control Valve Nova 227508 Piezo Ignitor 018744 Electrode 019407 H T Lead 019479K Motor Kit 010866 Cooling Disc 228116 Fan 200 x 40mm 010909 Motor Capacitor 4 f 01...

Page 27: ...en burners and griddle variations possible within the model specified Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 BSP F F Convertible Town Gas 230185 BSP F F Adjustable Model...

Page 28: ......

Reviews: