Waldorf RNB8910GC Installation And Operation Manual Download Page 11

Installation

 

Regulator connections are 

3

/

4

" BSP female. 

Connection to appliance is 

3

/

4

" BSP male. 

(Refer to ‘Specifications’ section for gas supply location dimensions). 

 

NOTE:  A Manual Isolation Valve must be fitted to individual appliance supply line. 

 

3. 

Correctly locate appliance into its final operating position and using a spirit level, adjust legs so 

appliance is level and at correct height. 

4. 

Connect gas supply to appliance.  A suitable jointing compound which resists breakdown action of 

LPG must be used on every gas line connection, unless compression fittings are used. 

5. 

Check all gas connections for leakages using soapy water or other gas detecting equipment. 

6. 

Check gas operating pressure is as shown in ‘Specifications’ section. 

 

NOTE:  Burner operating pressure is to be measured at manifold 

test point with 2 burners operating at ‘High Flame’ setting. 

 

7. 

Verify operating pressure remains correct. 

 
 
 

Electrical Connection 

NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED 

PERSON. 

 

Each appliance should be connected to an adequately protected power supply and isolation switch mounted 
adjacent to, but not behind appliance.  This switch must be clearly marked and readily accessible in case of 

fire. 

 

1. 

Check electricity supply is correct as shown on Rating Plate attached to front right hand corner of 

bottom sill. 

2. 

Appliance is fitted with a 10 Amp, 3 pin plug cordset for connection to a properly earthed, 3 pin 

switched electrical socket. 

 

Commissioning 

1. 

Before leaving new installation; 

a.  Check the following functions in accordance with operating instructions specified in ‘Operation’ 

section of this manual. 



Light the Open Burners.  (F - Flame Failure Option). 



Light the Open Burners.  (PF - Pilot and Flame Failure Option). 



Check the Low Fire Burner operation. 



Check the High Fire Burner operation. 



Light the Oven Pilot and Main Burners. 



Check the Oven Main Burner Thermostat operation. 



Check the Oven Fan operation. 

 

b.  Ensure operator has been instructed in areas of correct lighting, operation, and shutdown 

procedure for appliance. 

 

2. 

This manual must be kept by owner for future reference, and a record of 

Date of Purchase,

 

Date 

of Installation 

and 

Serial Number of Appliance 

recorded and kept with this manual.  

(

These 

details can be found on Rating Plate attached to front right hand corner of bottom sill.  

Refer to ‘Gas Connection’ section).

 

 

NOTE:  If it is not possible to get appliance to operate correctly, shut off gas supply and contact 

supplier of this appliance. 

Fig 2 

Manifold 

Test Point 

 
 

D

O

 

NOT

 

USE

 

A

 

NAKED

 

FLAME

 

TO

 

CHECK

 

FOR

 

GAS

 

LEAKAGES

Warning 

Summary of Contents for RNB8910GC

Page 1: ...s t a l l a t i o n a n d O p e r a t i o n M a n u a l RN8910GC RNL8910GC RNB8910GC RNLB8910GC Gas Range Convection Oven Date Purchased Serial Number Dealer Service Provider 232780 12 For use in GB...

Page 2: ...s tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455...

Page 3: ...n Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 10 Operation Guide Description of Controls Open Burners Oven Pilot Ignition Oven Main Burner Thermostat Oven Fan Turn...

Page 4: ...NCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE O...

Page 5: ...e Protection General A heavy duty general purpose gas convection oven range created for compact modular kitchens It is available on industrial adjustable feet or on robust rollers Open Burners are ava...

Page 6: ...inal 6 5 kW 7 8 kW 6 5 kW 7 8 kW Reduced 1 75 kW 1 75 kW Gas Rate nett Nominal 0 69 m3 hr 0 83 m3 hr 0 51 kg hr 0 61 kg hr Reduced 0 19 m3 hr 0 14 kg hr Supply Pressure 20 mbar 37 mbar Burner Operatin...

Page 7: ...roximately 130mm from right hand side 32mm from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions section Connection is BSP male thread Electrical Supply Requirements...

Page 8: ...6 Dimensions RN L 8910GC Cooktop Options...

Page 9: ...es and manufacturer s specifications shown in this section will void the warranty Components having adjustments protected e g paint sealed by the manufacturer are only to be adjusted by an authorised...

Page 10: ...wing checks should be made before installation a Gas Type the appliance has been supplied for is shown on coloured stickers located above gas connection and on rating plate Check this is correct for g...

Page 11: ...ed and readily accessible in case of fire 1 Check electricity supply is correct as shown on Rating Plate attached to front right hand corner of bottom sill 2 Appliance is fitted with a 10 Amp 3 pin pl...

Page 12: ...t Oven Fan Turning Oven to Stand By Mode Oven Shut Down 1 Description of Controls Heating Indicator Lamp Amber Power Indicator Lamp green Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burn...

Page 13: ...Main burner will extinguish and pilot will remain alight b To turn OFF the PILOT depress and turn gas control knob clockwise back to OFF position PILOT burner will extinguish Open Burners F Flame Fai...

Page 14: ...osition This puts gas valve in Stand By position and control of main burner is now carried out through oven thermostat control 4 Turn oven thermostat to desired oven temperature setting required this...

Page 15: ...cently been turned OFF and you want to re light oven the interlock will not allow gas valve to be turned to main burner position until interlock has reset Approximately 1 minute DO NOT FORCE GAS VALVE...

Page 16: ...rial has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical supply before c...

Page 17: ...pty spill tray and wash with warm soapy water 5 Dry all components thoroughly and re assemble Oven Interior Cleaning 1 Do not use wire brushes steel wool or other abrasive materials to clean oven inte...

Page 18: ...Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple fault...

Page 19: ...E CORDSET P N 7 BLUE 8 10 HEAT ORANGE CLEAR MICROSWITCH 003004 COM N O 13 12 E BLOCK TERMINAL E 12 GREEN 11 CAPACITOR BLACK BROWN BLUE BLACK BROWN GREEN MOTOR WHEN VIEWED FROM INSIDE OVEN FAN DIRECTIO...

Page 20: ...nds burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot sta...

Page 21: ...bracket Refit main burner and secure clamp bracket Refit sole plate s and lower lintel NOTE There is no Low Fire adjustment on the gas control valve for the GC Oven Refit oven control panel Gas Regula...

Page 22: ...ate Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in...

Page 23: ...ation Setting Fully Open Fully Open Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas G20 Propane G31 Open Burner Main Burner I...

Page 24: ...s Open Burner Main Burner 2 45mm 4 50mm Pilot Burner PF Option Only 0 30 0 60 Oven Main Burner 2 6mm 5 0mm Pilot Burner 0 35 0 60 Low Fire 1 5mm 2 50mm Burner Aeration Setting Fully Open Fully Open Su...

Page 25: ...30 026136 Pilot Injector LP Gas Butane 0 20 232309 Pilot Injector Town Gas 0 60 229442 Pilot Bracket Assembly 229444 Pilot Burner Shield 227403 Gas Control with Pilot and Flame Failure 227384 Knob Op...

Page 26: ...011987 Thermostat 50 320 C 230312 Gas Control Valve Nova 227508 Piezo Ignitor 018744 Electrode 019407 H T Lead 019479K Motor Kit 010866 Cooling Disc 228116 Fan 200 x 40mm 010909 Motor Capacitor 4 f 01...

Page 27: ...en burners and griddle variations possible within the model specified Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 BSP F F Convertible Town Gas 230185 BSP F F Adjustable Model...

Page 28: ......

Reviews: