4
Specifications
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
*
Measure burner operating pressure at manifold test point with 2 burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male thread.
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Open Burner
(each)
Heat Input
(nett)
Nominal
6.5 kW
6.5 kW
Reduced
1.75 kW
1.75 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr
0.51 kg/hr
Reduced
0.19 m
3
/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Connection
See ‘Gas Connection’ information overleaf
0.14 kg/hr
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18”w.c.)
Burner Operating Pressure
0.95 kPa (*)
(3.7” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection
See ‘Gas Connection’ information overleaf
28 MJ/hr
(26,540 Btu/hr)