22
Gas Conversion and Specifications
Conversion Procedure
NOTE:
These conversions should only be carried out by qualified persons. All connections must
be checked for leaks before re-commissioning the appliance.
Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) can
only be adjusted in accordance with the following instructions and shall be re-sealed
before re-commissioning this appliance.
For relevant gas specifications refer to
‘Gas Specifications Tables’
at end of this section.
Open Burners.
1.
Remove the following:-
Trivets
burner caps and burner bowls. Take care not to damage thermocouples.
Trivet supports,
(pilot shields - PF options only)
,
splash guards.
2.
Remove injectors and replace with correct size injectors as shown in ‘Gas Specifications Tables’ at
end of this section.
For F Options Only,
unscrew and
remove main injectors.
For PF Options Only,
unscrew and
remove main injectors and pilot injectors.
3.
Refit the following:-
Splash guards,
(pilot shields - PF options only)
.
Trivet supports, trivets, burner caps and burner bowls.
4.
Re-light main burners and check flame size on simmer (LOW) position.
Adjust low fire adjustment screw on open burner gas control
valves to obtain desired flame size.
NOTE: The 'Low Fire Screw' should be sealed with coloured paint on
completion of low fire adjustment.
Ensure that the Appliance is isolated from the gas supply before commencing
servicing.
Caution
Main Injector
Low Fire Screw
Main Injector
Pilot Injector