10
10. Verify that the supply pressure is still correct.
11. Check the Main Burner operating pressure (Adjust, using the ‘Operating Pressure Adjusting Screw’ on
the gas control valve, see Fig 3 on previous page), and as shown in the ‘Gas Conversion and
Specifications’ section, ‘Main Burner Operating Pressure Adjustment’.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each fryer should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the fryer. This switch must be clearly marked and readily accessible in case of
fire.
NOTE:
•
This appliance must be grounded / earthed.
•
Fixed wiring installations must incorporate an all-pole disconnection switch.
Commissioning
The following commissioning checks must be carried out before the fryer is handed over for
use, to ensure that the unit operates correctly and the operator(s) understand the correct
operating procedure.
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
'Operation' section of this manual.
b. The thermostat operation check should be carried out by filling the fryer with oil to the oil 'FILL
LEVEL' mark at the rear of the tank and setting the thermostat to 180°C. Light the pilot burners
and turn on the main burners in accordance with 'Operation Instructions' found in this manual.
NOTE: If using shortening, the fryer should be filled in accordance with 'Shortening'
instructions found in the ‘Operation’ section of this manual.
c. The calibration of the thermostat should be checked once the oil is up to temperature. If a
discrepancy is found, the thermostat calibration should be referred to the supplier.
d. Ensure that each operator has been instructed in the areas of correct lighting, operation, and
shutdown procedures for the appliance.
2.
This manual must be kept by the owner for future reference and a record of
Date of Purchase
,
Date of Installation
and
Serial Number of Unit
recorded and kept with this manual.
(These
details can be found on the Rating Plate attached to the inside of the access door. Refer
to the 'Gas Connection' section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off
the gas supply and contact the supplier of this unit.
Installation