12
Operation
Lighting Pilot Burners
FN8120 Fryer (Single Tank)
1.
Rotate gas control knob to
Pilot
position and hold knob
depressed.
2.
At the same time hold flame failure button depressed.
3.
Depress piezo igniter until right hand pilot ignites.
4.
Hold gas control knob and flame failure button depressed
for approx. 10 to 15 seconds after igniting pilot burner,
then release, both pilot burners should remain alight.
5.
If pilot burners do not ignite, repeat Items 1 to 4 above.
FN8130 Fryer (Single Tank)
1.
Rotate gas control knob to
Pilot
position and hold knob
depressed.
2.
At the same time hold flame failure button depressed.
3.
Depress right and left hand piezo igniters until right and
left hand pilots ignite.
4.
Hold gas control knob and flame failure button depressed
for approx. 10 to 15 seconds after igniting both pilot
burners, both pilot burners should remain alight.
5.
If pilot burners do not ignite, repeat Items 1 to 4 above.
FN8226 Fryer (Twin Tank)
1.
Rotate gas control knob to the position marked 'PILOT'
and hold depressed.
2.
Depress the piezo igniter until pilot ignites.
3.
Continue holding the gas control knob depressed for
approx. 10 to 15 seconds after igniting pilot burner, pilot
burner should remain alight.
4.
If pilot burner does not ignite, repeat Items 1 to 3 above.
5.
To ignite the second pilot burner, repeat Items 1 to 3
above with the second gas control valve.
Lighting Main Burners
1.
Ensure that pilot burners are alight.
2.
Depress and rotate gas control knob to
Full Flame
position.
3.
Main burners will ignite automatically off pilot burners.
NOTE:
If main burners are turned ‘On’ immediately after pilot burners are lit, a delay of
approximately 30 seconds will occur until the thermopile (which provides power to
open the main valve) has heated up from the pilot burners.
Main burners will not light if frying medium temperature is above thermostat set
temperature.
Turning gas control knob from pilot to main burner position will allow manual cycling
of burners ‘On’ and ‘Off’ when melting shortening.
Flame Failure
Button
Piezo Igniter
Gas Control
Valve
Fig 6
Piezo Igniter
Gas Control
Valve
Fig 8
Only Right Hand Valve Shown
Gas Control Valve
Left & Right
Piezo Igniters
Flame Failure
Valve
Fig 7
Fig 9
Summary of Contents for Fast-Fri FN8120G