PARAMETER OVERVIEW OF LEVEL 1 FOR USERS
Parameter
Value
Description
C11 External release
(remote)
off (factory setting) The device functions as a standalone device. External release
by interface does not have to be defi ned. The bypass is
activated.
on
If parameter C11 is set, the LED "External release" on the
control unit lights up continuously.
The external release by interface must be issued. If the trigger
is pulled despite the fact that no release has been issued, the
LED display "External release" starts to fl ash quickly.
Release is present when input is connected to GND.
C12 External
set value
specifi cation
off (factory setting) The set values for high-voltage in kV and current limitation
in μA are set at the operating panel.
on
The set values for high-voltage in kV and current limitation
in μA are predefi ned using the interface's two analog power
inputs.
Application example: Set value specifi cation by
superordinate control (PLC)
Set values can no longer be adjusted at the front control
panel. All recipe functions (save, call up recipe, etc.) are
locked.
C13 Lock
off (factory setting) Lock is deactivated.
on
Lock is activated, set values (kV and μA) cannot be changed,
user can only select recipes and control functions.
pro
Lock pro (program)
You can select recipes and control functions.
The target values (kV and μA) can be adjusted but cannot be
saved in the recipes.
7.7
DEVICE CONFIGURATION
Overview of the device confi guraton levels:
There are 3 levels:
Level 1:
for operator
Level 2:
for WAGNER Service
Level 3:
for WAGNER production plant
Summary of Contents for VM 5000
Page 2: ......
Page 42: ...42 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 65: ...65 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 66: ...66 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 67: ...67 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...