55
VM 5000
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03682
_22
12
14
15
OPERATING MANUAL
EDITION 08/2014
ORDER NUMBER DOC2318718
Code
display
Fault
Cause
Remedy
E11
Ground monitoring
- Grounding cable is interrupted
- Check/replace gun cable
- Check/replace gun
- Gun is not connected
- Connect gun
E12
No coil current/
cascade interrupt
- Gun is not connected
- Connect gun
- Gun cable is interrupted
- Check/replace gun cable
- Cascade in gun is interrupted
defective
- Check/replace gun
E13
Coil current too big
- Cascade of the connected gun is
defective
- Check/replace gun
E21-E29 Exception error
- Hardware defect has occurred
- If problem persists, contact the
WAGNER Service Team
E30
Cabinet door
monitoring
- In Aquacoat operation: switching
on the high-voltage with an
open door
- Close Aquacoat cabinet door
E40-E43 Gun communication
faulty
- Gun cable defective
- Check/replace gun cable
- Operating unit of spray gun
defective
- Wagner Service
- Control unit defective
- Wagner Service
E60
Password error
- Password not set
- Password to be set by Service
Center
The fault LED (12) indicates faults. In addition, the error number is shown in the 7-segment
display (15). If a fault occurs, the high voltage is immediately switched off . The user can
only continue to work once the fault has been remedied and acknowledged with push
button for service (14).
Summary of Contents for VM 5000
Page 2: ......
Page 42: ...42 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 65: ...65 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 66: ...66 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...
Page 67: ...67 VM 5000 OPERATING MANUAL EDITION 08 2014 ORDER NUMBER DOC2318718...